D D S S 2 2 0 0 0 0 S S u u b b s s t t r r o o b b e e s s
• DS200 SubStrobes with a Serial Number less than 7,1 63 require
an update to operate with the TTL Conversion Circuitry.
• DS200 Substrobes with a Serial Number of 7,1 63 or higher, or
with one of the two following labels in the battery compartment,
provide optimum performance with the TTL Conversion Circuitry.
ikelite
Substrobe
Substrobe
MOD-NC
U U s s i i n n g g E E x x t t e e r r n n a a l l S S t t r r o o b b e e s s C C o o n n t t . .
U U s s i i n n g g I I k k e e l l i i t t e e N N o o n n - - D D S S S S u u b b s s t t r r o o b b e e s s ( ( S S u u b b s s t t r r o o b b e e 5 5 0 0 , , 1 1 0 0 0 0 A A , ,
2 2 0 0 0 0 , , 4 4 0 0 0 0 ) ) w w i i t t h h t t h h i i s s H H o o u u s s i i n n g g . .
The Conversion Circuitry is automatically disabled when used
with a Non-DS Substrobe. These Substrobes can be used in their
manual mode utilizing any power settings provided on the
Substrobe.
U U s s i i n n g g N N o o n n I I k k e e l l i i t t e e S S t t r r o o b b e e s s w w i i t t h h t t h h i i s s H H o o u u s s i i n n g g . .
The Conversion Circuitry is automatically disabled when used
with a Non-Ikelite Strobe. These strobes can be used in their
manual mode utilizing any power settings provided on the strobe.
P P r r e e - - D D i i v v e e Y Y o o u u r r S S y y s s t t e e m m
It is recommended that you take the complete system into
a swimming pool before use in open water. This will give you
a chance to become familiar with the handling and operation
of your housing and strobe(s).
O O p p t t i i o o n n a a l l A A c c c c e e s s s s o o r r i i e e s s
P P o o r r t t O O ' ' r r i i n n g g # # 0 0 1 1 0 0 5 5 ( ( S S p p a a r r e e O O - - r r i i n n g g r r e e c c o o m m m m e e n n d d e e d d ) )
I I k k e e l l i i t t e e L L u u b b e e # # 0 0 1 1 8 8 4 4 . . 1 1
L L e e a a d d W W e e i i g g h h t t # # 0 0 9 9 0 0 6 6 . . 5 5 8 8
The buoyancy of the system will depend on the size and
number of strobes used as well as the weight of the camera.
Ideally the system should be slightly negative in the
environment in which it will be used. If you need to add weight
to the system, an optional lead weight is available. To add the
lead weight, remove the (2) screws from the bottom of the
aluminum tray. Place the lead weight into the pocket of the
aluminum tray and reattach.
H H o o u u s s i i n n g g B B a a c c k k O O ' ' r r i i n n g g # # 0 0 1 1 3 3 2 2 . . 6 6 1 1
While both the Port and Back o'rings should last quite some time
it is best to carry a spare in case one becomes damaged or lost.
S S t t o o r r i i n n g g t t h h e e H H o o u u s s i i n n g g
When the housing is going to be stored for a prolonged period,
it should be soaked in a mild soap solution, rinsed, and dried
thoroughly. Remove the back and port from the housing.
Remove the back and port o'rings, lightly lubricate them and
place them in a plastic zip-lock bag. Place the plastic bag inside
the housing for storage. Operate the push buttons periodically.
17
19
S S t t r r o o b b e e A A r r m m s s
This housing offers two types of arm mounting systems. The
top of the rubber handles utilize Ikelite's Quick-Release Arm,
available with the SA-1 00R Arm system.
The bottom of the rubber handles have a wing nut that accepts
the Ikelite Tray Mount. The Tray Mount comes with the Ikelite
SA-1 25 Arm system and the SA-1 00T Arm system.
L L u u b b r r i i c c a a n n t t s s
1 . Ikelite provides silicone lubricant with the housing. We
recommend that you use only Ikelite lubricant as some other
brands may cause the o'ring to swell and not seal properly.
2. Use only enough lubricant to lightly cover control shafts and
o'rings. Wipe off any excess lubricant with a clean cloth.
Lubricant is not a sealant, it is used to reduce friction. Excessive
lubricant can collect sand and dirt which may interfere with
proper sealing.
C C A A U U T T I I O O N N
N N e e v v e e r r u u s s e e s s p p r r a a y y l l u u b b r r i i c c a a n n t t s s a a s s t t h h e e p p r r o o p p e e l l l l a a n n t t i i n n g g r r e e d d i i e e n n t t c c a a n n
c c a a u u s s e e t t h h e e p p l l a a s s t t i i c c h h o o u u s s i i n n g g t t o o c c r r a a c c k k . .
P P o o r r t t I I n n f f o o r r m m a a t t i i o o n n / / w w w w w w . . i i k k e e l l i i t t e e . . c c o o m m
While we have included a list of our ports and a short list of Olympus
Lenses and port recommendations, we suggest visiting our web site
for the latest information on lenses and port recommendations.
•With the lens on the camera extended
to full length, measure from the front of
camera to the face of lens.
•Select the appropriate port based on the
lens type and length.
•Maximum lens diameter accommodated
is 8.4cm (3.3")
•Maximum lens diameter when using
standard zoom or focus clamp is 7.1 cm
Measure
(2.8"); 2.8-3.0" diameter lenses with
#5509.28 zoom set (included w/housing)
C C h h o o o o s s i i n n g g a a P P o o r r t t
D D O O M M E E P P O O R R T T
#5503........Wide angle 28mm to 1 7mm
or lens up to 7.6cm (3") in length
#5503.20 ..Nikon 1 8 & 20mmD lenses
#5503.50 ..Lens 7.6-1 0.1 cm (3-4")
#5503.55....Lens 8.9-1 1 .4cm (3.5-4.5")
#5503.80 ..Lens 1 0.1 -1 2.7cm (4-5")
#5503.85 ..Lens 1 2.7-1 5.2cm (5-6")
Some zoom lenses that will not focus to a minium of 1 2
addition of a +4 diopter close-up lens. (Available from camera store).
S S U U P P E E R R W W I I D D E E D D O O M M E E P P O O R R T T
Superwide lens 1 1 0° to 1 70°.
#5503.1 5 Lens up to 6.3cm (2.5")
18
"
will require the
20

Advertisement

loading