ADAPTING THE APPLIANCE TO FUNC-
TION WITH DIFFERENT TYPES OF GAS
If a different gas from that one indicated on
the label is used, adapt the cooktop to this
new function.
Injectors for LPG gas can be obtained
from the After-Sales Service.
Select the injectors to be replaced
according to the TABLE FOR THE
CHOICE OF THE INJECTORS.
The nozzle diameters, expressed in hun-
dredths of a millimetre, are marked on
the body of each injector.
Fig. 5.2
GAS MAINTENANCE
OPERATIONS TO BE PERFORMED
WHEN SUBSTITUTING THE INJECTORS
To replace the injectors:
The burners are conceived in such a
way so as not to require tthe regula-
tion of the primary air.
J
Remove the gratings, the burner cov-
ers and the knobs;
Using a wrench substitute the nozzle
injectors "J" (Fig. 5.3 - 5.4) with those
most suitable for the kind of gas for
which it is to be used.
Fig. 5.3
J