Electrical Adjustment
Grp / No. Item
18
Normal Fan1 Min
19
Normal Fan1 Max
20
Normal Fan2 Min
21
Normal Fan2 Max
22
Normal Fan3 Min
23
Normal Fan3 Max
24
Normal Fan4 Min
25
Normal Fan4 Max
26
Normal Fan5 Min
27
Normal Fan5 Max
28
Normal Fan6 Min
29
Normal Fan6 Max
30
Normal Fan7 Min
31
Normal Fan7 Max
32
Eco Fan Control Min Temp
33
Eco Fan Control Max Temp
34
Eco Fan1 Min
35
Eco Fan1 Max
36
Eco Fan2 Min
37
Eco Fan2 Max
38
Eco Fan3 Min
39
Eco Fan3 Max
40
Eco Fan4 Min
41
Eco Fan4 Max
42
Eco Fan5 Min
43
Eco Fan5 Max
44
Eco Fan6 Min
45
Eco Fan6 Max
46
Eco Fan7 Min
47
Eco Fan7 Max
255
Fan Start/Cooling Setting
0
Fan1 Initial Volt
1
Fan2 Initial Volt
2
Fan3 Initial Volt
3
Fan4 Initial Volt
4
Fan5 Initial Volt
5
Fan6 Initial Volt
6
Fan7 Initial Volt
8
Cooling Time
10
Temp Error Cooling Time
11
OnStart Cooling Start Threshold
12
After shutdown cooling
256
Fan Lamp Voltage Down Setting
0
Lamp Voltage
1
Lamp Vol Threshold
2
Fan1 Speed Gain
3
Fan2 Speed Gain
4
Fan3 Speed Gain
5
Fan4 Speed Gain
257
Fan Setting at Dimmer
0
Dimmer Average Check Period
259
Fan Air Pressure Setting
0
Press Source Range Low
1
Press Source Range High
6
Press Fan Add Range High
7
Press Fan Add Range Low
8
Press Fan Add Range High
9
Press Fan Add Range Low
10
Press Fan Add Range High
11
Press Fan Add Range Low
12
Press Fan Add Range High
13
Press Fan Add Range Low
17
Temp A Warning Normal Highland Temp A (Room) to judge the Temp Error at Normal/Highland
Function
Fan Spinning Set at Normal (Min/Max) (0.1V)
Temp Sensor Control Start/End Temp at Eco
Fan Spinning Set at Eco (Min/Max) (0.1V)
Fan Start Voltage (0.1V)
Coolong Time Setting (x30 sec.) 1: 30 3: 90 15: 450
Cooling Time Setting When the Temp Error occurs (x30 sec.)
1: 30 3: 90 15: 450
Cooling Operation after Shut Down (0: No, 1: Yes)
Current Lamp Voltage (1V) (Read only)
Threshold Voltage (1V)
Fan Speed Ad Gain (0.1V)
Dimmer Average Check Period (sec.)
0: 10, 1: 30, 2: 60, 3: 90......10:300
Pressure Sensor Control Range (AD)
Add value of Fan control for Lamp Fan at Normal
Add value of Fan control for other fans at Normal
Add value of Fan control for Lamp Fan at Eco
Add value of Fan control for other fans at Eco
Range
0000-9990
70
0000-9990
138
0000-9990
60
0000-9990
138
0000-9990
35
0000-9990
35
0000-9990
60
0000-9990
138
0000-9990
70
0000-9990
100
0000-9990
55
0000-9990
55
0000-9990
56
0000-9990
98
20-100
25
20-100
37
0000-9990
45
0000-9990
120
0000-9990
42
0000-9990
120
0000-9990
35
0000-9990
35
0000-9990
45
0000-9990
120
0000-9990
55
0000-9990
80
0000-9990
40
0000-9990
40
0000-9990
45
0000-9990
98
0-255
0-255
0-255
0-255
0-255
0-255
0-255
1-15
1-15
0-100
0-1
0-255
30-90
0-1500
0-1500
0-1500
0-1500
0-10
0-1023
0-1023
0-5000
0-5000
0-5000
0-5000
0-5000
0-5000
0-5000
0-5000
0 - 100
-56-
Initial
Note
70
70
70
138
138
138
60
60
60
138
138
138
55
55
35
60
60
35
60
60
60
138
138
138
70
70
70
100
100
100
35
35
60
35
45
60
56
65
56
98
98
98
26
26
26
37
35
35
45
45
45
120
120
120
42
42
42
120
120
120
40
40
35
40
40
35
45
45
45
120
120
120
55
55
55
80
80
80
35
35
40
35
35
40
50
55
45
98
98
98
45
45
45
45
65
45
55
3
3
38
1
---
30
0
10
10
10
1
661
398
10
30
20
40
5
15
20
40
48