3. ALIGNMENT FOR FM TUNING VOLTAGE
a.
Required Instruments
DVM
b.
Alignment Procedure
Mode
Adjustment
FM
L1
c.
Instrument Connection
(1) Turn on the radio.
(2) Connect the probe of DVM to the TP29 and TP4.
(3) Tune the FM frequency to 108MHz.
(4) Adjust L1 to have a reading of 7.2V ±0.3V.
TP29
TP4
Procedure
L1
DVM