Installation Instructions KWT 1603 SF en - CA Installation, repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations and the provided installation instructions.
Caring for the environment Disposing of the packaging Disposal of your old appliance materials Old appliances may contain materials that can be recycled. Please contract The packaging is designed to protect your local recycling authority about the the appliance from damage during possibility of recycling these materials.
Installation Climate Range In areas with a tropical climate The appliance is designed for use (over 100°F/38°C and more than within certain climate ranges (ambient 70% air humidity) the wine cooler temperatures) and should not be used must only be operated in air outside this range.
55 °F (13 °C) or rise above hard, rigid material. 110 °F (43 °C), otherwise malfunctions may occur. If in doubt, contact Miele. If installation next to a heat source is unavoidable, observe the following Furniture/fixtures minimum distances from the heat...
Page 5
See "Niche dimensions". Miele. The side walls of the installation cavity must be plumb. Contact Miele or your dealer for specific information about which The minimum thickness of the side combinations will work with your walls and the top wall must be 5/8"...
The "Merging Kit" will also be needed. The "Merging Kit" is available from Miele. Installation with partition without using the "Merging Kit" If there is a partition with a thickness of more than 6 "...
Page 7
Dimensions Door dimensions (open min. 90°) KWT 16X3 SF 26 " (677 mm)
Dimensions Power supply 1. Power supply KWT 16X3 SF 12" (305 mm) Power bars or extension cords are not safe (risk of fire). Do not use them to connect the appliance to the power supply.
Installation Before you begin – Multi-grip pliers – Level Read these instructions completely and carefully. – Tape measure Have the appliance installed by a – Square qualified technician, according to When fastening the cabinet to the wall the enclosed installation behind it (see "Installing the appliance") instructions.
Installation Aligning the housing unit Check the installation niche To ensure a safe, trouble-free installation and the best possible cosmetic result, check to be sure that the installation space complies with the installation requirements. ^ Check the base (see "Installation"). ^ Check the dimensions of the cavity.
Do not install the appliance if it is installation niche. visibly damaged. If in doubt, contact Once connected the RemoteVision Miele. module will increase the energy consumption of the appliance. The slot for the RemoteVision module is located in the lower area of the back of your appliance.
Page 13
If you would like to connect your installation of the module was appliance to the Home Security unsuccessful. In that case, repeat the System, proceed now (see "Home process. If that does not correct the Security System"). problem, contact Miele.
Installation Home Security System (HSS) If desired, the wine storage unit can be connected to the security system of your house, via a switching contact. If connected, you will be immediately informed of rising temperatures in the wine cooler. The Home security system connection must be hooked up before the unit is installed.
Installation Preparing the installation Anti-tip-brackets niche The anti-tip brackets a keep the appliance safely secured in the Keep the appliance door closed installation niche b and prevent it from until it is securely fastened in the tipping. niche. Tipping hazard. Because of the size and weight of the appliance, it is essential to ensure that the appliance cannot tip...
Page 16
Installation In a cabinet with a back wall ^ Position the anti-tip brackets on the left and right in the installation niche so that there is no more than 3/8" (10 mm) of space between the brackets and the side walls. ^ Mark the drill holes in the anti-tip brackets on the back wall and on the ceiling of the installation niche.
Page 17
Installation In a cabinet without a back wall Securing an alternative anti-tip device If the anti-tip brackets cannot be attached securely, an alternative anti-tip device can be used. Ensure that there is no "give" between the appliance and the anti-tip device. If possible, always screw the wooden beam to existing studs.
Page 18
Installation Sliding the appliance into the – The beam must cover the appliance by at least 2" (50.8 mm). installation niche ^ Mark the installation height (lower If a side-by-side installation is edge of the beam) on the rear wall of desired, connect the two appliances the niche.
Installation ^ Plug the appliance into the power Aligning the appliance outlet a. ^ Align the appliance with the surrounding cabinets. The plug of the appliance should be easily accessible after installation. If the plug is not accessible after the appliance has been installed, disconnection from the power supply should be completed via the...
Installation ^ Unscrew the height-adjustable feet Attaching the appliance to the until the mark on the base has installation niche reached the indicated guide dimension 1 1/4" (32 mm). The guide dimension of 1 1/4" (32 mm) is related to a niche height of 84" (2134 mm).
Page 21
Installation Attaching the toe-kick cover The maximum height of the toe-kick cover is 4" (102 mm) from the top of the floor. Do not cover ventilation slits in the plinth. Risk of damage to the appliance. ^ If required, cut the toe-kick cover to the required length and height.
Page 22
Installation ^ Position the air separator in the Mounting the air separator center of the appliance door. The air separator keeps the supply and exhaust air separate. This prevents warm exhaust air from flowing into the machine, optimizing the energy performance of the unit.
If there are any questions regarding the electrical connection of this appliance to the power supply, please consult a licensed electrician or call the Miele Technical Service. U1-800-999-1360 V1-800-565-6435...
'virtual link' between your following requirements appliance and our monitoring center. If – A wireless router that supports an a fault occurs, Miele's client service IEEE 802.11b/g protocol center will be notified and contact you, ® or another trusted individual identified –...
Page 25
RemoteVision (optional accessory) ^ Tap the X button until ; appears in Accessing the RemoteVision the display. control panel ^ Touch the access button "p" to confirm. See the table on the following page for a description of each setting in the ^ Touch the access button "p"...
Page 26
RemoteVision (optional accessory) MasterCool control panel options for RemoteVision Status indicators Description of function Flashing ; ~ Module booting phase Flashing ; ‡ Not connected to network Flashing ; | Connection to network established, no IP address assigned Solid Connected to network Flashing ;...
Page 31
KWT 1603 SF KWT 1613 SF en - US, CA M.-Nr. 09 920 900 / 00...