WS-TS-2500 This manual describes the installation and operation of the Brand “WoodPRO” wood heater. This heater meets the 2015 U.S. Environmental Protection Agency's crib wood emission limits for wood heaters sold after May 15th 2015. Under specific test conditions this heater has been shown to deliver heat at rates ranging from XXX to XXX Btu/hr.”...
Page 2
firebox. This stove has not been DO NOT CONNECT THIS UNIT TO A CHIMNEY tested with the use of grates, andirons or other means FLUE SERVING ANOTHER APPLIANCE. of elevating the fire and must not be used. Page 2 WoodPRO™...
Page 3
It is against TION WITH ANY AIR DISTRIBUTION DUCT WORK federal regulations to alter this setting or otherwise UNLESS SPECIFICALLY APPROVED FOR SUCH operate this wood heater in a manner inconsistent with operating instructions in this manual. INSTALLATIONS. Page 3 WoodPRO™...
NOTE: Mobile home installations require OTE: SERIAL NUMBER / SAFETY LABLE IS double-wall UL 103 HT high-temp connector LOCATED ON BACK OF UNIT. pipe. Secure connector pipe to the flue collar with three (3) equally spaced sheet metal screws to WoodPRO™ Page 5...
PIPE SIZING 2. Horizontal pipe runs must slope upwards NOTE: PIPE IS NOT INCLUDED. TO PURCHA- towards the chimney at least 1/4˝/6.4mm per foot SE VISIT YOUR LOCAL HARDWARE, HOME, of horizontal run. OR BUILDING CENTER. 3. You must have at least 18˝/457mm of clearance ADDITIONAL SPECI- between any horizontal piping and the ceiling.
CHIMNEY CONNECTIONS MASONRY CHIMNEY The stove must be connected to either a lined ma- sonry or manufactured metal chimney built and tested The chimney must be a code-approved, masonry to the specifications listed on the previous pages. chimney with flue liner. Before using an existing ma- Chimneys perform two functions: sonry chimney, clean the chimney, inspect the flue 1).
Page 14
...continued CHIMNEY CONNECTIONS MANUFACTURED CHIMNEY REFER TO CHIMNEY AND CHIMNEY CONNEC- TOR MAKER’S INSTRUCTIONS FOR INSTALLATION AND USE. Use only 6˝/152mm diameter manufactured chim- ney system listed to UL 103 HT (US) or ULC-S629 (CAN). Chimney made to this listing is High Tempera- ture rated to 2100°F/1149°C.
Page 15
...continued CHIMNEY CONNECTIONS 8˝/203mm of liner must remain below the entry tified Chimney Sweep, or a knowledgeable inspector. position. When locating the stove and stovepipe, all Consult your insurance company if you cannot find a minimum clearances must be observed from com- qualified expert.
CHIMNEY CONNECTOR SYSTEMS & CLEARANCES NFPA 211 (US) NOTE: In Canada, installation must conform to CAN/CSA-B365 when passing through combustible construction. A. Brick Masonry Minimum 3.5˝/89mm thick brick masonry all framed into combustible wall with a minimum of 12˝/305mm brick separation from clay liner to combustibles.
OPERATING INSTRUCTIONS CAUTION: HOUSE FIRE HAZARDS This heater is designed to burn natural wood only. DO NOT STORE WOOD ON FLOOR PROTECTOR, Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods, as UNDERNEATH STOVEPIPE, OR ANYWHERE compared to softwoods or to green or freshly cut WITHIN MINIMUM CLEARANCES FROM hardwoods.
...continued OPERATING INSTRUCTIONS height, weather, log size, wood species and moisture P r o p e r c u r i n g o f t h e h i g h - t e m p p a i n t content.
OPERATING INSTRUCTIONS ...continued Fuel load size can vary but should be kept 1–2˝ 7. Once fuel has been loaded, close the door and (25mm-50mm) below the secondary air tubes. Also leave the air inlet control fully open until fire is well position the fuel to leave space so the air from the inlet established (at least 15–20 minutes) being careful can work between the pieces of fuel.
This wood heater needs periodic inspection and Whenever ashes get 3 to 4 inches deep in your repair for proper operation. It is against federal firebox or ash pan, and when the fire has burned regulations to operate this wood heater in a manner down and cooled, remove excess ashes.
SERVICE PARTS When requesting service or replacement parts for your appliance, please provide model number and serial number. All parts may be ordered by calling 1-877-427-3316.
Page 26
SERVICE PARTS When requesting service or replacement parts for your appliance, please provide model number and serial number. All parts may be ordered by calling 1-877-427-3316. Pkg of 6 Pkg of 4 Pkg of 4...
SERVICE PARTS When requesting service or replacement parts for your appliance, please provide model number and serial number. All parts may be ordered by calling 1-877-427-3316.
Page 28
SERVICE PARTS When requesting service or replacement parts for your appliance, please provide model number and serial number. All parts may be ordered by calling 1-877-427-3316. Pkg of 6 Pkg of 6 Pkg of 4...
SERVICE PARTS When requesting service or replacement parts for your appliance, please provide model number and serial number. All parts may be ordered by calling 1-877-427-3316.
Page 30
SERVICE PARTS WS-TS-2500 When requesting service or replacement parts for your appliance, please provide model number and serial number. All parts may be ordered by calling 1-877-427-3316.
BLOWER MAINTENANCE & WIRING DIAGRAM BLOWER MAINTENANCE The optional blower is maintenance free other than cleaning. Lightly vacuum motor and air inlet to keep free of dust and dirt. CAUTION: MOVING PARTS CAN CAUSE DANGER: SHOCK HAZARD. DISCONNECT INJURY. DO NOT OPERATE WITH COVER POWER SOURCE BEFORE INSTALLATION REMOVED.
FLOOR PROTECTOR MATERIAL CALCULATIONS This stove has been tested for and must be installed on a floor protector with the proper Thermal Resistance or R-value as stated in step 1 of the installation instructions under “Locating Stove” section of this manual. If the floor protector ma- terials listed in the instructions are not available, materials with an equivalent R-value may be substituted.
This warranty covers components of the WoodPro appliances as listed in the table below. Warranty Coverage: Subject to the table below, HHT warrants to the owner of the WoodPro appliance that the appliance will be free from defects in materials and workmanship at the time of manufacture. After installation, if covered components are found to be defective in materials or workmanship during the applicable warranty period, HHT will replace the covered components.
Need help?
Do you have a question about the WS-TS-1500 and is the answer not in the manual?
Questions and answers
Blower squeaks