Neil Anthony Hughes
April 4, 2025

Digi Door installed, remote function has stopped working, Ho to set it up again

User image 67efe83872f70
1 comments:
Mr. Anderson
May 14, 2025

To set up the remote function again for the Hydro Doors Digidor III, follow these steps:

1. Power on the system.
2. Press and hold the light toggle button.
3. The light will turn on. After 5 seconds, it will go off—continue holding the button.
4. After another 5 seconds, the light will flash 6 times, confirming a complete erase.
5. Only the master wireless wall console will remain functional.
6. To record a new transmitter, use the wireless wall console.

For full reset including the master console, refer to the Factory Reset instructions on page 14.

This answer is automatically generated

Summary of Contents for Hydro Doors Digidor III

  • Page 1 HYDRO DOORS Quality Access Technology...
  • Page 2 +27 11 474 9067 / 8739 5. Features and Specifications Website: www.hydrodoors.co.za Email: sales@digidoor.co.za, 6. General Issues LAMBERT ANDERSON WOOD TRAINING ACADEMY (DIVISION OF HYDRO DOORS) Types of doors to be automated Telephone: +27 11 474 9060 Condition of doors Facsimile:...
  • Page 3 Frequently examine the door and operator for wear, damage and improper balance. Serial Number: …………......Installation Date: ………………….………………. Installed By: …………………………………………………………………………………………....Ensure that a Hydro Doors accredited installer services the Installer’s Accreditation Number: ………………………………………………………………....door regularly Door Service Record Obstacle sensing is done electronically and must be properly adjusted.
  • Page 4: In The Box

    8. Accessories 3. Contents of the Box Emergency Key Release The emergency key release is required where a garage has no service door. The key release allows the door to be manually released from the outside in the case of a power failure or low battery condition.
  • Page 5: Features & Specifications

    8. Accessories 4. Features & Specifications 24 Vdc Motor with integrated gearbox: A purpose-made 24vdc motor Battery backup developed for the door industry, which has a greater power to weight ratio and greater efficiency than 12v motors, powers the digidoor III The digidoor III ac/dc has an optional battery backup feature which will allow operation during ac/dc.
  • Page 6: Troubleshooting

    Note! To erase the master wireless wall console see Factory reset page 14 Hydro Doors and Gates (Pty) Ltd (Hydro) warrants the first purchaser of the digidoor III ac/dc, that the product shall be free of any defects in materials and/or workmanship for a period of twelve EXTERNAL CONNECTIONS months (one Year) from the verifiable date of purchase.
  • Page 7: Assembly/Installation

    Remove power (including battery power if fitted.) (Disconnect the batteries by No representative or person is authorized to assume for Hydro Doors any other liability in unplugging the 2-way connector on the battery charger board. Fig. 6, p16) connection with the sale of this product.
  • Page 8 6. Assembly & Installation 6. Assembly & Installation Visual and audible indications: WIRELESS WALL CONSOLE Mounting the Wireless Wall Console Using the screws and screw-plugs provided, mount the Wall Console to the wall in a convenient position, out of the reach of children. Note! Only the first wall console (master) will enable the user to record transmitters and complete the erase all function described on page 16.
  • Page 9 6. Assembly & Installation 6. Assembly & Installation Fig.3 Fig.4 ELECTRICAL CONNECTIONS AND SET-UP Note 1: If the Set-up needs to be repeated for any reason, refer to Factory Reset p15. Secure the foot-end of the Drive Strut assembly to the anchor bracket while supporting the motor. Open the door and vertically align the Drive Strut assembly to the door centre line.
  • Page 10 50mm) and open the door fully by hand. With the door open, mark, Fig.3 drill and secure the wall-bracket to the wall. Tighten the setscrews of the wall-mount bracket. Important! Springs to be greased, regularly checked and adjusted. If necessary, contact an Accredited Hydro Doors Installer.