Desa VDL18PR Owner's Operation And Installation Manual page 9

Table of Contents

Advertisement

INSTALLATION
Continued
CAUTION: This heater cre-
ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or where impurities
(such as, but not limited to, to-
bacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls or cause odors.
IMPORTANT: Vent-free heaters add moisture to
the air. Although this is beneficial, installing heater
in rooms without enough ventilation air may cause
mildew to form from too much moisture. See Air
for Combustion and Ventilation, page 6.
CHECK GAS TYPE
Use the correct gas type (natural or propane/LP)
for your unit. If your gas supply is not correct, do
not install heater. Call dealer where you bought
heater for proper type heater.
WARNING: This appliance
is equipped for natural or pro-
pane/LP gas. Field conversion
is not permitted.
INSTALLATION AND CLEARANCES
FOR VENT-FREE OPERATION
WARNING: Maintain the
minimum clearances. If you
can, provide greater clearances
from floor, ceiling and adjoining
wall.
111035-01F
MINIMUM FIREPLACE CLEARANCE TO
Log Size
18", 4",
30" and 36"
Log
Size
18"
4"
30"
36"
* Measured at 14" depth.
Carefully follow the instructions below. This will
ensure safe installation into a masonry, UL127-
listed manufactured fireplace or listed vent-free
firebox.
Minimum Clearances For Side
Combustible Material, Side Wall and
Ceiling
A. Clearances from the side of the fireplace
cabinet to any combustible material and wall
should follow diagram in Figure 4.
Example: The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3
tible material must be 4" from the side of the
fireplace cabinet (see Figure 4).
Note: When installing your gas logs into
a manufactured firebox, follow firebox
manufacturer's instructions for minimum
clearances to combustible materials.
B. Clearances from the top of the fireplace opening
to the ceiling should not be less than 42".
*Minimum 16" from Side Wall
Figure 4 - Minimum Clearance for
www.desatech.com
COMBUSTIBLE MATERIALS
Side Wall
16"
LOG SIZING REQUIREMENTS
Minimum Firebox
Height Depth
17"
14"
17"
14"
17"
14"
17"
14"
/
" from the wall. This combus-
1
2
Example
Combustible to Wall
Ceiling
4"
Front
Rear *
Width
Width
4"
0"
8"
1"
34"
4"
40"
30"
*
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vdl24prVdl30prVdl36pr