BELLSYSTEM PRACTICES
SECTION 502-543-403
AT&TCo Standardlssue
7, December 1980
SERVICE
2565GK,
2565GKM,
AND 2565GKMS
TELEPHONE SETS
CONNECTIONS
1.
GENERAL
cord
conductors
can be
extended
to
the control
unit
by
using
a 149-type
adapter
or
66E-type
1.01
This
section
contains
information
for the
connecting
block.
If control
unit is located
at the
2565GK (MD), 2565GKM (MD), and 2565GKMS
key equipment,
extend
the leads
through
an A25B
telephone
sets
(Fig. 1 and 2).
connector
cable or inside wiring cable.
Speakerphone
connections
are shown
in Division
512.
1.02
This section
is reissued
to"
2.04
SWhen
a 2565GK
(MD) or 2565GKM
[(MD)
. Show 2565GKM
telephone
set MD
manufactures
prior to July 20, 1979] telephone
set
is not
used
as a speakerphone
set
and
is
. Add information
on 2565GKMS telephone
set
multipled
with any other
set capable
of furnishing
speakerphone
feature,
the T1 (V-G) and R1 (G-V)
. Add D-181006 Kit of Parts
(Polarity
Guard)
speakerphone
leads must be disconnected,
insulated,
and stored at the telephone
set.
If not disconnected,
e Add
information
on
the
533K
diode
(or
these
speakerphone
leads
will provide
a common
equivalent)
which replaces
KS-15724L1
diode,
path between
the circuits
of the multipled
telephone
sets.
Speakerphone
connections
are
shown
in
1.03
SThe 2565GKMS
telephone
set is similar
to
Division
512.4
the 2565GKM
set except the new line switch
is provided
on the 2565GKMS
which
breaks
both
2.05
Exclusion
can be provided
by the
addition
the tip and ring side of the line instead
of the ring
of a D-179935
Kit of Parts
which
must
be
side only.¢
ordered
separately.
Connect
as shown
in Table
A.
2.
CONNECTIONS
2.06
SWhen
a polarity
guard
is required
with
these
sets, a D-181006 Kit of Parts
(ordered
2.01
These
sets
are
factory-wired
for use with
separately)
can be installed
and connected
as shown
1A1, 1A2, 6A, or 6B key telephone
systems
in Table B.¢
(KTS), 4A speakerphone,
and individual
or common
line ringer.
They
can be used with
1A KTS by
2.07
An
812559623
(P-25E962)
terminal
strip
modifying
as shown
in Fig. 3 and 4.
Hold feature
assembly
(ordered
separately)
is available
is not provided,
when
additional
terminating
points
are
required
for auxiliary
services
such as buzzers,
lamps,
etc.
2.02
Early
model
sets
were
furnished
from
the
factory with H1A (MD) ringer, current
models
2.08
Installation
instructions
for
the
exclusion
have
H1B ringer.
Provision
is made
for
buzzer,
switch, polarity
guard, and auxiliary
terminal
ordered
separately.
Use spare
pair and terminals
strip
are given
in Reference
Section
502-500-120.
to connect
to equipment.
When
power
failure
feature
is provided
in
the
KTS,
audible
signal
2.09
All convertible
key positions
are supplied
as
must
be wired
with
capacitor
in circuit,
pickup
keys
To
convert
from
pickup
(locking) to signaling
(nonlocking),
remove the screw
2.03
If 3-type (MD) speakerphone
control
unit is
detail
from key positions
involved.
Make necessary
located
near the telephone
set, the mounting
wiring
changes
as shown
in Table
C.
NOTICE