MODELS: WT-46807 / WS-55807 / WS-55857 / WS-55907 /WS-65807 / WS-65857 / WS-65907 / WS-73907
Note: Perform only the adjustments required.
Do not attempt an alignment if proper equipment is not available.

1. Test Equipment

• Oscilloscope (Unless otherwise specified, use 10:1 probes)
• Signal Generator (both SD and HD capable)
• Frequency Counter
• Direct Current Voltmeter
• Direct Current Power Supply
• Multiplex Audio Signal Generator
• Direct Current Ampere Meter
2. Test Signals
A. Monoscope Signal
When called for, use the NTSC or HD 1080i
monoscope signal shown.
B. Color Bar Signal
Use the color bar signal shown
below, unless otherwise specified
in this manual.

3. Initial Setup

A. Option Menu Setup
Follow the steps below for the initial set-up:
1. Select the "MENU" display by pressing the "MENU" button once.
2. Press the number buttons "8", "2", "7", "0" in sequence to
select the "OPTION MENU" display.
3. Press the "ADJUST" button to select "INITIAL."
4. Press "ENTER."
NOTE: At this time channel 3 is automatically selected.

ELECTRICAL ADJUSTMENTS

100%
75%
40%
40%
Split-Field Color Bars (100% window)
Page 22
Monoscope Signal
1H
(MENU-8-2-7-0)
OPTION MENU
Initial
Power restore
DTV Port
:OFF
:Auto