Advertisement

U
S
E
R
'
S
M
A
N
U
A
L
U
S
E
R
'
S
M
A
N
U
A
L
Emergency Backup Power Supply
For Use With Computer Loads Only
Power Surge/Noise Protection
Intelligent Auto-Shutdown Software
Cost Efficiency
Internet Line Protection
UPS
Uninterruptible Power System
Compact & Reliable Design
AVR Protection

Advertisement

Table of Contents
loading

Summary of Contents for Repotec RPT-1000A

  • Page 1 Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software ℡ Cost Efficiency Internet Line Protection Uninterruptible Power System Compact & Reliable Design AVR Protection...
  • Page 2: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS Thank you for selecting this uninterruptible power system (UPS). It provides you with better protection for connected equipment. Please read this manual! This manual provides safety, installation and operating instructions than will help you derive the fullest performance and service life that the UPS has to offer.
  • Page 3 NOTES CAUTION The UPS contains voltage that are potentially hazardous. All repairs should be performed by qualified service personal. The UPS has its own internal energy source (battery). The output receptacles may be alive even when the UPS is not connected to an AC supply.
  • Page 4: Specifications

    SPECIFICATIONS SYSTEM CONCEPT The purpose to present this chapter is to give you more precise conception about how UPS works.. Capacity 800VA 1000VA 1. Block Diagram 100VAC, 110VAC, 120VAC, 220VAC, 230VAC or 240VAC Voltage ±25% Input INPUT OUTPUT 50Hz or 60Hz ±5% Frequency N.F.
  • Page 5: Computer Interface

    COMPUTER INTERFACE OVERVIEW The computer interface (DB9 port) on the back of the UPS may be Front Panel connected to a host computer. This port allows the computer to monitor the Master Power Switch: Turn on/off the UPS. status of the UPS and control the operation of the UPS. Green LED: AC Normal .
  • Page 6 CONTENTS PAGE 1. CAUTION…………………………………………………………..…..1 2. INTRODUCTION SYSTEM DESCRIPTION………………………….……………..2 FEATURES………………………………….……………………..2 3. SYSTEM CONCEPT BLOCK DIAGRAM……………………………….………………..3 NORMAL OPERATION………………………….………………..3 AC UTILITY FAILURE………………………….…………………4 4. OVERVIEW FRONT PANEL……………………………………………………5 REAL PANEL………………………………………………………5 PICTURE…………………………………………………….…….5 5. INSTALLATION AND OPERATION…………………………………7 6. COMPUTER INTERFACE……..…………………………………….8 7. BATTERY FACTS……………………………………………………..9 8. SPECIFICATIONS……………………………………………………10 9. TROUBLE SHOOTING………………………………...……………11 10.
  • Page 7: Trouble Shooting

    INTRODUCTION TROUBLE SHOOTING If the UPS failed to operate properly, please review the following checks System Description firstly. If the problem remain, please consult sales agent for service. The product is line interactive UPS with the newest technology and powerful Is the Master power switched on? function.
  • Page 8: Battery Facts

    BATTERY FACTS 3. AC Utility Failure The battery is the only periodically serviceable parts in the UPS. An If AC utility fails, the UPS quickly detects the problem and activates the expected life is approx. 3∼5 years. However, frequent long discharges or inverter.
  • Page 9: Installation And Operation

    INSTALLATION AND OPERATION Rear Panel: Upon receipt of the UPS, inspect the shipping carton for damage. If there is 3 2 1 3 2 1 any obvious damage, immediately report it to the selling dealer or the delivering carrier. If there is no damage to the shipping carton, unpack the REM OTE REM OTE unit and inspect the unit for damage.

Table of Contents