17.) Open the flex connector with the SS-34 flex
connector-opening tool. Mind the surrounding
components while placing the tool. Now the UI-Frame
Assy can be removed.
19.) Remove the Earpiece with the dental tool
21.) Unlatch the BB shield Assembly first.
23.) Pull the UI Frame Assy slightly to unlock the UI
PWB.
Service Manual N70 Level 1&2
PAGE 14 (26)
CONFIDENTIAL
18.) Unlatch each clip of the LCD from the UI Frame
Assy carefully by pulling the UI Frame Assy sideward
while pushing the LCD forward.
20.) Also remove the Earpiece Gasket from its
compartment.
Always use a new gasket when
reassembling.
22.) Then push down and remove the BB Shield
Assembly. The shield can't be reused again, always use
a new one.
24.) Now the UI PWB can be removed easily.