Royal english oak and winchester oak unvented (vent-free) natural gas log heater 18" and 24" variable manually-controlled and 24" thermostatically-controlled models (33 pages)
Summary of Contents for Comfort Glow Sedona LSLR18
Page 1
VENTED DECORATIVE NATURAL GAS LOGS OWNER’S OPERATION AND INSTALLATION MANUAL RGA 2-72 TesTed and LisTed By APPROVED SEDONA MODELS LSLR18 AND LSLR24 WARNING: If the information in this manual is not fol- lowed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
WARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a qualified installer, service agency or the gas supplier. WARNING: This appliance is for installation only in a solid-fuel burning masonry or UL127 factory-built fireplace, constructed of noncombustible material and...
SAFETy INFORMATION WARNING: This appliance is equipped for natural gas. An op- WARNING: This product con- tional propane/LP conversion kit tains and/or generates chemicals model GA9200 must be installed known to the State of California for use with propane/LP gas. to cause cancer or birth defects or other reproductive harm.
10. To help prevent breakage, new logs must be SAFETy INFORMATION broken-in (see Curing Logs page 9). Continued 11. Turn log set off and let cool before servicing, 1. If you smell gas installing, or repairing. Only a qualified service •...
The fireplace must include a working flue and UNPACkING venting system with the minimum openings shown Continued in the Figure 2. 2. Remove all protective packaging applied to logs and base for shipment. Burner Btu Input Minimum Descrip- Natural Vent 3.
Page 6
Installation must include an equipment shutoff INSTALLATION valve, union, and plugged 1/8" NPT tap. Locate Continued NPT tap within reach for test gauge hook up. NPT tap must be upstream from log set (see Figure 4). INSTALLING DAMPER CLAMP Secure the damper stop clamp provided to the leading IMPORTANT: Install equipment shutoff valve edge of the damper as shown in Figure 3.
3. Check all joints from gas meter to equipment INSTALLATION shutoff valve (see Figure 5). Apply noncorro- Continued sive leak detection fluid to gas joints. Bubbles forming show a leak. CHECKING GAS CONNECTIONS 4. Correct all leaks at once. WARNING: Test all gas piping HEARTH KIT ASSEMBLY AND and connections, internal and INSTALLATION...
Page 8
INSTALLATION INSTALLING THE GRATE AND LOGS 1. Place the grate over the burner pan where the Continued two outer horizontal supports on the grate fit OPTIONAL GA9200 SERIES ON/OFF into the two pan positioning tabs on the outer edges of the pan. SAFETY VALVE/PILOT KIT For additional convenience and safety an optional 2.
3. Wait five (5) minutes to clear out any gas. If INSTALLATION you then smell gas STOP! Follow the safety Continued information column 1. If you don't smell gas, go on to the next step. 4. Light a match and lay it on top of the pan material about 2"...
CLEANING AND REPLACEMENT PARTS Note: Use only original replacement parts. This MAINTENANCE will protect your warranty coverage for parts • Keep the area around the log set clean and clear replaced under warranty. of debris. • Occasionally, you may use a soft bristle brush PARTS UNDER WARRANTY to clean logs.
TROUbLESHOOTING WARNING: Turn off log set and let cool before servicing. Only a qualified service person should service and repair log set. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Log set is smoking/sooting 1.
Page 12
TROUbLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.
ACCESSORIES GLOWING EMBERS - GA9950A Purchase these log set accessories from your local (Not Shown) For all models. Use for firebox decoration only. dealer. If they can not supply these accessories, call DESA at 1-866-672-6040 for referral infor- SILICA SAND - GA9850A mation.
PARTS LIST This list contains replaceable parts used in your log set. When ordering parts, follow the instructions listed under Replacement Parts on page 10 of this manual. PART NO. DESCRIPTION QTY. 901056-01 3/8 FLR x 1/ FPT adapter • •...
WARRANTy INFORMATION kEEP THIS WARRANTy Model serial no. date Purchased Always specify model and serial numbers when communicating with the factory. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. LIMITED LIFETIME WARRANTy - VENTED GAS LOGS DESA warrants this product to be free from defects in materials and components of the burner system for two (2) years and a lifetime on logs from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
Need help?
Do you have a question about the Sedona LSLR18 and is the answer not in the manual?
Questions and answers