OPERATION

TEMPERATURE-DISPLAY

In normal use, the display shows the inside temperature of the appliance. This temperature is
displayed in °C with one decimal place.
During times without solar energy supply or in case of power failure the display is switched off. The
inside temperature can be checked by pressing the "TMP" button.

TEMPERATURE-SETPOINT

The temperature setpoint is preset at +5.0°C and cannot be changed by the user.
Press the SET-key to view the actual temperature setpoint.

STORAGE OF VACCINES

IMPORTANT :
When using the TCW3000SDD, it is of utmost importance that the icelining waterpacks are in
place. Make sure that all waterpacks are in place before starting the TCW3000SDD in refrigerator
mode. Never remove the waterpacks from the unit.
Special care should be taken to preserve the vaccines that get damaged by freezing. Never store
them touching the side surfaces in the cabinet of a TCW3000SDD. It is advisable to preserve the
vaccines in the provided baskets.
For storing vaccines :
Keep the packets containing the vaccines in
neat rows.
Different vaccines should be kept separately to
facilitate easy identification.
Keep about 2 cm space between rows for
circulation of air.
Do not load vaccines higher than the indicated
maximum level.

USING THE TCW3000SDD

Install the TCW3000SDD as detailed under "Installation".
Shift the ON/OFF-switch to position "I". The temperature display lights up to show that the unit is
ready for operation.
After switching on, the compressor only starts after a delay of 3 minutes. This also applies, if the
equipment is switched off and on again.
Close the lid and allow the unit to run. The temperature inside the cabinet is indicated on the
display. Observe the temperature from time to time.
Initially the temperature inside the TCW3000SDD will be observed to be similar to or slightly below
the room temperature. It will decrease slowly and remain steady after several days.