GEM-MFI SERIES
For the Plumber
Water Inlet:
●Remote Cooled Models:
The recommended water supply is cold water. Use 3/8 inch O.D. copper tubing, connect to the 3/8 FPT on the
back of the cabinet. Install a hand valve near the machine to control the water supply.
Drains:
●Remote Cooled Models:
There is one 3/4 inch FPT drain at the back of the cabinet; the drain line is of the gravity type, and 1/4 inch per
foot fall is an acceptable pitch for the drain tubing. There should be a vent at the highest point of the drain line,
and the ideal drain receptacle would be a trapped and vented floor drain. Use only ¾ inch rigid tubing.
Storage Bin:
Install a separate gravity type drain. Insulation of this drain line is recommended.
Water Inlet 3/8 FPT
Page 13