MEH-P7100R,P7150
- Adjustment point
KEYBOARD UNIT(SIDE B)
mV Meter
TP3
VR1902
TP1
<When the OEL Unit has been replaced>
1. ACC ON while pressing the 1 and 3 keys together after RESET START.
2. Pressing the 1 and 3 keys together after SOURCE ON. (All indication lighting mode)
3. Use VR1902 to adjust the difference in potential between TP1 and TP3(GND) to 1.07V.
• All indication lighting mode cancellation
Switch ACC, back-up OFF.