5-2 Mechanical Adjustment

Note : Refer to the Mechanical Manual for the adjustment and confirmation of ass'y deck.

5-2-1 The number and position of test point

Test point :
TP601 (Control Pulse)
TP602 (H'D S/W -Trigger)
TP301 (Envelope)
TP302 (Audio output)
TP303 (Video output)
TE
L 13942296513

5-2-2 ACE Head Position (X-Point) Adjustment

(See the 5-2-1(d) ACE Head Position (X-Point) Adjustment on
page 5-2 of the Mechanical Manual)
1) Playback the alignment tape (KRV-52NE (NTSC) /
52PL (PAL)).
www
2) Monmently short-circuit the test point on Main PCB with
pincers to set the adjustment mode.
(See Fig. 5-2)
.
3) Press the "5" button of remote control then adjustment is op-
erated automatically. (See Fig. 5-1)
http://www.xiaoyu163.com
AUDIO OUTPUT
ENVELOPE
HEAD SWITCHING
Fig. 5-4 Location of Test point (Main PCB-Top View)
x
ao
u163
y
i
http://www.xiaoyu163.com
2 9
8
Q Q
3
6 7
1 3
1 5
4) Connect the CH-1 probe to TP301 (Envelope) the CH-2
probe to TP602 (H'D switching pulse) and then trigger
to CH-1.
5) Insert the (-) driver into the X-Point adjustment hole
and adjust it so that envelope waveform is maximum.
6) Turn the Power off.