Note : *1
• Capacity is based on the following temperature conditions.
Temperature
Indoor unit inlet air temperature
Outdoor unit inlet air temperature
Notes : *2
CHARGELESS
RAS-10SKH-ES
• No additional refrigerant required.
• This air conditioner accepts a connection piping length of up to 10m and a head of up to 5m.
• There is no need to add the refrigerant as long as the total length of the connection piping is up to 10m.
RAS-13SKH-ES
• No additional refrigerant required.
• This air conditioner accepts a connection piping length of up to 15m and a head of up to 6m.
• There is no need to add the refrigerant as long as the total length of the connection piping is up to 15m.
Condition
(DB)
(WB)
(DB)
(WB)
– 4 –
JIS C9612-1994
Cooling
27°C
19°C
35°C
24°C
Heating
20°C
12°C
7°C
6°C