How To Use The Gh-702A; Maintenance And Repair - Cherry GH-702A Maintenance Manual

Table of Contents

Advertisement

HOW TO USE THE GH-702A

After selecting the proper pulling head and attaching it securely to the GH-702A, connect the air line to the tool. Insert the rivet
stem into the pulling head until the head of the rivet is in contact with the pulling head sleeve. This will ensure full engagement
between the jaws and the rivet stem and will prevent slippage.
Once the rivet stem is inserted in the pulling head, the rivet must be installed. Insert the rivet into the application and pull the
trigger to activate the tool. Upon the release of the trigger, the stem will eject to the rear of the tool.

MAINTENANCE AND REPAIR

The GH-702A has been manufactured to give maximum service with minimum care. In order that this may be accomplished, the
following recommendations should be followed:
1. The hydraulic system should be full of oil and free from air at all times.
2. Keep excessive moisture and dirt out of air supply to prevent wear of air valve, air cylinder and air piston.
3. Tool should be routinely inspected for oil leaks.
Use automatic transmission fluid Type "A" (no substitutes). Cherry Aerospace recommends using ATF, Dexron III oil.
FIRST AID
Skin: Wash thoroughly with soap and water as soon as possible. Casual contact requires no immediate attention. If
irritation develops, consult a physician.
Ingestion: Seek medical attention immediately. DO NOT INDUCE VOMITING.
Eyes: Flush with copious amounts of water. If irritation develops, consult a physician.
Inhalation: No significant adverse health effects are expected to occur on short term exposure. Remove from contaminated area.
Apply artificial respiration if needed. If unconscious, consult physician.
FIRE
Suitable extinguishing media: CO
ENVIRONMENT
Waste Disposal: In accordance with local, state and federal regulations.
Spillage: Prevent entry into drains, sewers and water courses. Soak up with diatomaceous earth or other inert material. Store in
appropriate container for disposal.
HANDLING
Eye protection required. Protective gloves recommended. Chemically resistant boots and apron recommended. Use in well ventilated area.
COMBUSTIBILITY
Slightly combustible when heated above flash point. Will release flammable vapor which can burn in open or be explosive in
confined spaces if exposed to source of ignition.
STORAGE
Avoid storage near open flame or other sources of ignition.
PROPERTIES
Specific gravity
Weight per gallon
DEXRON III OIL SAFETY DATA
, dry powder, foam or water fog. DO NOT use water jets.
2
0.863
7.18 lbs.
3

Advertisement

Table of Contents
loading