Bottom Mount Refrigerator⎯Technical Information
MFD 2561HEB MFD 2561HEB0, MFD 2561HEQ MFD 2561HEQ0,
MFD 2561HES MFD 2561HES0, MFD 2561HEW MFD 2561HEW0
Due to a possibility of personal injury or property damage, always contact an authorized technician for
service or repair of this refrigerator.
All safety information must be followed as provided in Service Manual 16025629.
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power
before servicing unless testing is required. Discharge capacitors through a 10,000 ohm resistor before
handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper
grounding and polarization.
Kw/24 hr ±0.4
Ambient °F
70°
90°
25 cu ft
1.2
1.80
Evaporator
Outlet
±3°F
Ambient °F
70°
25 cu ft
-20
Schematic
June 2005
© 2005 Maytag Services
!
!
No-Load Performance, Controls in Normal Position
Percent Run Time
±10%
110°
70°
90°
110°
2.6
32
51
75
Temperature Relationship Test Chart
Evaporator
Inlet
±3°F
90°
70°
90°
70°
-17
-20
-17
85
CAUTION
WARNING
Refrigerator Center
Cycles/24 hr
Temperature ±3°F
±25%
70°
90°
110°
70°
28
24
19
38
Suction Line
Average Total
±7°F
Wattage ±10%
90°
70°
105
135
1
Compartment
Freezer Compartment
Average Food
Average Food
Temperature ±3°F
90°
110°
70°
90°
38
38
0
Suction
Pressure
Head Pressure
±2 PSIG
90°
70°
90°
70°
140
0
0
83
110°
0
0
± 5 PSIG
90°
135
16026365

Advertisement

Table of Contents
loading

Summary of Contents for Maytag MFD 2561HEB

  • Page 1 Bottom Mount Refrigerator⎯Technical Information MFD 2561HEB MFD 2561HEB0, MFD 2561HEQ MFD 2561HEQ0, MFD 2561HES MFD 2561HES0, MFD 2561HEW MFD 2561HEW0 Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.
  • Page 2: Component Specifications

    Brown side 35w,Yellow side 20w Super Cool Fan Rotation (facing end opposite leads) Counterclockwise 1530 ± 250 RPM…………………………………… Watt…………………………………… 1.2 @ 12 VDC Light switch / Interlock Type…………………………………….. SPDT NO/NC Volt……………………………………… 125/250 VAC Current………………………………….. 8/4 amps 16026365 June 2005 © 2005 Maytag Services...
  • Page 3: Service Specifications

    The Control Board adapts the compressor run time between defrosts to achieve optimum defrost intervals by monitoring the length of time the defrost heater is on. After initial power up, defrost interval is 4 hours compressor run time. Defrost occurs immediately after the 4 hours. June 2005 16026365 © 2005 Maytag Services...
  • Page 4: Service Test Mode

    Service Test – 111 Fresh Food Fan (if equipped) • Press the Refrigerator Up eypad and Refrigerator Down eypad to toggle Fresh Food Fan On and Off. NOTE: Display will show state OFF or DC voltage. 16026365 June 2005 © 2005 Maytag Services...
  • Page 5 Service Test – 163 Water Dispenser (if equipped) • Display shows the state of the Water Dispenser (ON or OFF). NOTE: By pushing Actuator pad or Bottle fill you can control state of Water dispenser. June 2005 16026365 © 2005 Maytag Services...
  • Page 6 LED Indicators. All LED Indicators will flash. Press twice and LED will stop flashing. Service Test – 191 Ice Maker Water Valve • Display shows the state of the Ice Maker Water Valve (ON or OFF). 16026365 June 2005 © 2005 Maytag Services...
  • Page 7 NOTE: Temperature will read in Fahrenheit regardless of what current temperature scale is being used. Service Test – 221 Reset Default Settings • Press the Refrigerator Up Keypad and Down Keypad to force to dEF (default factory settings). June 2005 16026365 © 2005 Maytag Services...
  • Page 8: Wiring Diagram

    12923201 12923201 16026365 16026365 June 2005 June 2005 © 2005 Maytag Services © 2005 Maytag Services...

This manual is also suitable for:

Mfd 2561heb0Mfd 2561heq0Mfd 2561heqMfd 2561hesMfd 2561hes0Mfd 2561hew ... Show all

Table of Contents