Door Replacement - Electrolux EI24MO45IBA Technical & Service Manual

Table of Contents

Advertisement

Component Teardown and Testing

Door Replacement

Removal
1. Disconnect the power supply cord.
2. Push the open button and open the door slightly.
3.
Insert a putty knife (thickness of about 0.5mm) into
the gap between the choke cover and door frame as
shown in Figure 4-7 to free engaging parts.
4. Pry the choke cover by inserting a putty knife as
shown Figure 4-7.
5. Release choke cover from door panel.
6. Now choke cover is free.
7. Release two (2) pins of door panel from two (2) holes
of upper and lower oven hinges by lifting up.
8. Now, door panel with door frame is free from oven
cavity.
NOTE: When carrying out any repair to the door, do not
bend or warp the slit choke (tabs on the door panel
assembly) to prevent microwave leakage.
9. Release the door panel from twelve (12) tabs of door
frame.
10. Remove the door panel from the door frame.
11. Now, door panel with sealer film is free.
12. Tear sealer film from door panel.
13. Now, door panel is free.
14. Slide latch head upward and remove it from door
frame with releasing latch spring from door frame and
latch head.
15. Now, latch head and latch spring are free.
16. Remove door screen from door frame
17. Now, door frame is free.
Re-Install
1. Re-install door screen to door frame.
2. Re-install the latch spring to the latch head. Re-install
the latch spring to the door frame. Re-install latch
head to door frame.
3. Re-install door panel to door frame by fitting twelve
(12) tabs of door frame to twelve (12) holes of door
panel.
4. Put sealer film on door panel. Refer to "Sealer Film"
about how to handle a new one.
5. Catch two (2) pins of door panel on two (2) hole of
upper and lower oven hinges.
6. Re-install choke cover to door panel by pushing in.
Choke Cover
Figure 4-7. Choke Cover
After any service to the door:
(A) Make sure that door sensing switch, primary
switch and secondary switch are operating
properly.
(B) An approved microwave survey meter should be
used to assure compliance with proper micro-
wave radiation emission limitation standards.
After any service, make sure of the following :
1. Door latch heads smoothly catch latch hook through
latch holes and that latch head goes through center
of latch hole.
2. Deviation of door alignment from horizontal line of
cavity face plate is to be less than 1.0mm.
3. Door is positioned with its face pressed toward cavity
face plate.
4. Check for microwave leakage around door with an
approved microwave survey meter.
(Refer to Microwave Measurement Procedure.)
The door on a microwave oven is designed to act
as an electronic seal preventing the leakage of
microwave energy from oven cavity during cook
cycle. This function does not require that door be
air-tight, moisture (condensation)-tight or light-
tight.
Therefore, occasional appearance of moisture, light
or sensing of gentle warm air movement around
oven door is not abnormal and do not of them-
selves indicate a leakage of microwave energy from
oven cavity.
4-8
Door Frame
Putty Knife

Hide quick links: