Toshiba FT-8989 Service Manual page 19

Table of Contents

Advertisement

3. The base and handset cannot be connected.
Check whether the base
is able to set in the test
mode 1.
OK
Check the TX POWER
and the TX FREQUENCY
on the base unit.
OK
Set the base in the test
mode 3, check whether
deviation of the TX data
is app. 8.5 kHz Dev.
OK
Set the base in the test
mode 8, 902.952467
MHz (250 Hz ±8 kHz
Dev.) 1mV output signal
from RF test point is
a p p l i e d .
D o e s t h e
CHARGE LED light?
OK
Check whether the
handset is able to set in
the test mode 1.
OK
Check the TX POWER
and the TX FREQUENCY
on the handset unit.
OK
A
NG
Check IC6 and its
peripheral circuit.
NG
Check base RF unit.
Check whether there is a
NG
250 Hz data waveform at
"MOD" of RF unit.
OK
Check base RF unit.
NG
Check whether there is a
250 Hz data waveform at
RT2 AF test point.
OK
Check whether there is a
250 Hz data waveform at
the Q2 collector.
OK
Check whether there is a
250 Hz data waveform at
pin 44 of IC6.
OK
Check IC6 and its
peripheral circuit.
NG
Check IC603 and its
peripheral circuit.
NG
Check handset RF unit.
Check RT3, R51, R52,
NG
R53, R48, R80, R81,
C59, C135 and C54.
NG
Check IC2, Q1 and their
peripheral circuit.
OK
NG
Check RT2, Q2 and their
peripheral circuit.
NG
Check IC3 and its
peripheral circuit.
20
NG
Check base RF unit.

Hide quick links: