Summary of Contents for ecoteck ILARIA

  • Page 1 Pellet stove ILARIA www.ecoteck.it Operation and maintenance manual Pellet stove ILARIA www.ecoteck.it Operation and maintenance manual...
  • Page 2 MANUAL ILARIA MAINTENANCE DATE OPERATION PERFORMED ILARIA MANUAL MAINTENANCE DATE OPERATION PERFORMED...
  • Page 3 Description of the operation and maintenance manual This operation and maintenance manual is supplied by ecoteck with the aim of providing the user with all the information on the operating safety of the stove, so as to avoid damage to things or people or to the parts of the stove.
  • Page 4: Table Of Contents

    MANUAL MANUAL ILARIA ILARIA CONTENTS 1. Foreword ..........................pag. 5 Pellet stove ILARIA 2. Safety information ......................... pag. 5 3. Introduction ........................... pag. 5 3.1. Liability ........................... pag. 6 Warranty coupon 3.2. Spare parts ........................pag. 6 3.3. What are pellets? ......................
  • Page 5: Pag. 19

    7.5.3. Language ........................pag. 21 7.5.4. Stove status ....................... pag. 21 Ecoteck srl thanks you for the trust you have shown by purchasing the ILARIA pellet stove and kindly 7.5.5. Operating hours menu ....................pag. 21 asks you to: 7.5.6. Display settings menu ....................
  • Page 6: Safety Information

    The flue gas exhaust pipe or the flue will need to be cleaned more thoroughly, and the condition The ecoteck pellet stove ILARIA will prove how quality and economy can go hand in hand with very of the firepot must be checked, ordering a replacement from your reseller if required. If necessary, high performance, reduced consumption and total practicality.
  • Page 7: Liability

    The glass is automatically cleaned by a flow of air; nonetheless, a slight grey film will tend to form on the glass after a few hours of operation. As mentioned previously, the ILARIA pellet stove must be fed with pellets with a diameter of 6 mm, however it can also be made to operate with pellets of different diameters;...
  • Page 8: Safety Device

    4. Safety devices The ILARIA pellet stove features sophisticated safety systems that, if one of the parts breaks or there are faults in the flue, prevent damage to the stove and the home. In any case, when a problem occurs, the pellet feed system is immediately stopped.
  • Page 9: No Flame In The Fireport

    MANUAL MANUAL ILARIA ILARIA In any case, when a problem occurs, the pellet feed system is immediately stopped. Only a clean and unblocked firepot will ensure trouble-free operation of the pellet stove. During operation, There are two main “mechanical” safety devices: deposits may form in the firepot, and these must be removed immediately.
  • Page 10: Assembly, Installation And Start-Up

    MANUAL MANUAL ILARIA ILARIA 5. Assembly, installation and start-up 8. Cleaning and maintenance 5.1. Assembly Before performing any maintenance operations on the stove, adopt the following precautions: 5.1.1. Dimensions - Check that all the parts of the stove are cold.
  • Page 11: Minimum Distance Between The Stove And The Other Materials

    -side wall of the stove 20 cm -shelving above 20 cm -floor protection 20cm These indications may change due to regional or national standards. Always comply with the standards in force in the country where the stove is installed (contact your authorised ecoteck reseller). -10- -21-...
  • Page 12: Installation

    P4 enables/disables the operation of the stove. The operation of the pellet stove ILARIA is independent of the draught of the chimney, as the flue This parameter indicates the heat output when PROGRAM 1 is running.
  • Page 13: Menu Function

    Check that the firepot is correctly positioned. Day 6 Saturday Day 7 Sunday Disabled For any other problems contact your ecoteck installer UT02 This parameter is used to set the current hour UT03 This parameter is used to set the current minutes -19- -12- MANUAL...
  • Page 14: Operation

    MANUAL MANUAL ILARIA ILARIA 7. Operation Pressing button P3 for a few seconds cancels the message from the display. 7.1. Electronic board HOT FUMI [HOT FLUE GAS] The alarm is signalled if the flue gas probe reads a temperature above 280°C.
  • Page 15: Description Of The Controls And The Simbols On The Display

    MANUAL MANUAL ILARIA ILARIA 7.1.2. Description of the controls and the symbols on the display 7.3.4. Economy phase (or flue gas modulation) The flue gas modulation phase occurs if the flue gas temperature reaches the maximum threshold of 250°C (parameter Pr14) or the room temperature reaches the “SET TEMPERATURE”. During this phase, the flue gas exhaust fan and the exchanger are operated at maximum speed, while the screw conveyor operates at minimum speed;...
  • Page 16: User Function

    MANUAL MANUAL ILARIA ILARIA Display The LCD shows all the messages required for the operation of the stove. 7.3.1. Ignition phase IR Receiver The stove is started by pressing the ON/OFF button for a few seconds. The procedure starts IR receiver for remote control (optional).