Sharp LC-26SB25E Service Manual page 38

Hide thumbs Also See for LC-26SB25E:
Table of Contents

Advertisement

LC-26SB25E/S/RU, LC-32SB25E/S/RU, LC-42SB55E/S/RU
Are the power cord and harness in the unit properly connected?
↓ YES
LINE_FILTER_UNIT:
Is F901 normal?
↓YES
POWER_UNIT
Is BD901 (+320V) output? (Set the main power SW to OFF.)
* When power on/off switch is on ‧‧‧ About +400V
Is a voltage of +5V applied to pin (11,12) of connector (CN902)?
(Set the main power SW to OFF.)
Are +24V output as for the power on/off switch when it is on?
Similarly, is +12V output as for the power on/off switch when it is
on?
Power unit operation check(for LC-32SB25 and LC-26SB25).
↓YES
↓YES
↓YES
NO
Connect the power cord and harness properly, and turn on the
power.
LINE_FILTER_UNIT:
Isn't L901,L902,RV901,C903,C904,C901,C902, etc. out of
order?
Moreover,
NO
circumference circuit is checked.
POWER_UNIT:
BD901, RV902, IC951, etc. out of order?
Moreover, whether the short-circuit with the circumference circuit
is checked.
NO
Does the PFC circuit operate normally?
(L906, Q901, D902, D903,
the protection circuit etc. is checked.)
NO
Does the switching circuit operate normally?
Check circuit around the primary side (T901, IC931, Q931,
ZD981, ZD930, D980, D981, ZD981, etc.), the secondary side
(D935, L980, etc.), the AC_DET circuit (ZD982, IC932, IC982,
Q992, Q993, etc.), and the protection circuit.
Does the inverter circuit operate normally?
NO
Check circuit around the primary side (T902,Q951,Q952,IC951,
D951,D952, etc.), the secondary side (D955, L971, ZD967,
IC952, IC953, etc.), the STANDBY circuit (Q988, etc.), and the
protection circuit.
Check +12V circuit of D956, L931, etc.
NO