14.2.4 Calling up diagnostics levels
Menu ¬ Installer level ¬ Diagnostics menu
You can use the diagnostics menu to inspect parameters
and modify certain parameters. An overview of all diagnos-
tics codes can be found in ¬ table 12.1.
14.2.5 Overview of diagnostics codes at installer
level
Display Meaning
D.000
Heating partial load
D.001
Pump overrun for heating mode
D.002
Max. burner anti-cycling time heating at 20 °C flow
temperature
D.005
Flow temperature target value (or return target value)
D.006
Hot water temperature target value
D.007
Warm start temperature target value
D.010
Heating pump status of the pump group
D.011
Status of external heating pump
D.014
Target value for pump speed
D.016
Room thermostat 24 V DC at terminal 3'-4' (only NL)
D.017
Heating flow/return regulation changeover
D.018
Pump operating mode setting
D.022
Hot water demand via C1/C2, internal hot water control
system
D.023
Summer/winter operating mode (heating on/off)
D.025
Hot water generation enabled by eBUS controller
D.027
Switching of relay 1 on the
"2 in 7" multi-functional module VR 40
D.028
Switch of relay 2 on the "2 from 7" multi-functional
module VR 40
14.2 Diagnostics codes at installer level
ecoTEC plus installation and maintenance instructions 0020134823_01
Display value/adjustable value
Adjustable heating partial load in kW
(Factory setting: auto: Unit automatically adjusts max. partial load to
current system demand)
2 - 60 minutes (factory setting: 5)
2 - 60 minutes (factory setting: 20)
In °C, max. of the value set in D.071, limited by an eBUS controller if
connected
35 to 65 °C
40 to 65 °C
1 = on, 0 = off
1 to 100 = on, 0 = off
Heating circuit pump target value in %
0 = auto (default setting)
1 = 53
2 = 60
3 = 70
4 = 85
5 = 100
0 = Room thermostat open (no heating mode)
1 = Room thermostat closed (heating mode)
0 = flow, 1 = return (default setting: 0)
1 = Comfort (continuously operating pump)
3 = Eco (intermittently operating pump, default setting)
1 = on, 0 = off
1 = Heating on, 0 = Heating off (summer mode)
1 = Yes, 0 = No
1 = Circulation pump (default setting)
2 = Ext. pump
3 = Charging pump
4 = Extractor hood
5 = Ext. solenoid valve
6 = Ext. error message
7 = Not active
8 = Remote control eBUS (not active)
9 = Anti-legionella pump (not active)
1 = Circulation pump
2 = Ext. pump (factory setting)
3 = Charging pump
4 = Extractor hood
5 = Ext. solenoid valve
6 = Ext. error message
7 = Not active
8 = Remote control eBUS (not active)
9 = Anti-legionella pump (not active)
Troubleshooting