Download Print this page

Whirlpool 6ADG 952/3 WHM Service Manual page 3

Advertisement

S E R V I C E
Technical data
Flow rates / Inlet volume
Flow meter (at 0.3 bar
= quantity 1.1 l/min)
Spray pump
Drain pump
Pump height max.
Inlet valve
Valve for Zone washing
Spray arm lower
Sprayarm upper
Ceiling rotor
Electrical data
Base data
Voltage
Frequency
Total power
Fuse
Motor
Spray pump motor
Voltage
Power consumption
HI
HA
Capacitor
Drain pump motor
Voltage
Power consumption
Resistance
Heating
1 Element system
Voltage
Power consumption
Resistance
Heating speed
Temperature on surface
Safety thermostat
self reset
Whirlpool Europe
Customer Service
208
lmp/l
~ 70
l/min
16
l/min
1.1
m
4.5
l/min
30
l/min
~ 33
l/min
~ 27
l/min
~ 10
l/min
220/230
V
50
Hz
2.0-2.2
kW
10
A
220/230
V
160
W
81
44
µ F
4
220/240
V
30
W
146
220/230
V
1.87/2.04 kW
24.5
~ 2.0
˚C/min
~ 115
˚C
85
˚C
6ADG 952/3 WHM
8542 952 53410
Potentiometer
Points of meassurement: 1(black) to 2 (middle)
Position 0
Position 1
Position 2
Position 3
Position 4
Position 5
Position 6
Water valves
Single valve at inlet hose
Voltage
Frequency
Resistance
Valve for zone washing
Voltage
Frequency
Resistance
Coil of dispenser
Voltage
Frequency
Resistance
Reedcontact
flow meter
rinse aid control
NTC
20 ˚C
25 ˚C
30 ˚C
40 ˚C
50 ˚C
60 ˚C
70 ˚C
80 ˚C
85 ˚C
Accesory
If you need spare parts apart from
the spare part list have a look
in the Service Bulletin 4812 718 40084.
13.12.2000 / Page 3
Doc. No: 4812 718 15955
0.0
kΩ
0.5
kΩ
1.0
kΩ
1.4
kΩ
1.8
kΩ
2.3
kΩ
2.6
kΩ
220/240
V
50/60
Hz
3.76
kΩ
220-240
V
50/60
Hz
4
kΩ
220/240
V
50/60
Hz
1.5
kΩ
58.1
kΩ
47 .1
kΩ
38.2
kΩ
25.4
kΩ
17 .2
kΩ
11.8
kΩ
8.3
kΩ
6
kΩ
4
kΩ

Hide quick links:

Advertisement

loading