5.
After the self-diagnosis operation
The results display is not automatically cleared. In case of repairs and after repairs, check the self-diagnosis screen and be sure
to return the results display to " 0 ".
If the results display is not returned to " 0 " it will not be possible to judge a new malfunction after completing repairs.
<Method of Clearing Results Display>
1. Power off (Set to the standby mode)
2.
3. Channel 8 b 12
<Method of Ending Self Diagnosis Screen>
When ending the self-diagnosis screen completely, turn the power switch OFF on the remote commander or the main unit.
AUDIO PROT
(FROM A BOARD)
LOW-B ERR
(FROM A BOARD)
HV-PROT
(FROM D BOARD)
OVP
(FROM A, D BOARD)
AC-RLY
(TO A BOARD)
OCP
(FROM A, D BOARD)
• I2C YCJ RETURN DATA
1
LED
BLINKING
SYMPTOM
TIMES
2
+B OCP
+B OVP
3
V-STOP
4
AKB
5
LOW-B ERROR
6
H-STOP
7
AUDIO PROT
8
9
Z DET
HV PRT
10
b
5 b
+ b
=/1
(Test reset = Factory preset condition)
HV PROT
OVP
MAIN MICRO-
COMPUTER
IC101
M306V2
OCP
1
1
1
1
(Service Mode)
MJ BOARD
12C BUS
12C BUS
YCJ IC201
CXA-2170Q
1
1
1
– 7 –
KV-HR36M90
PF
MICRO-
COMPUTER
IC102
RM-1007