To range
Manifold
test point
pressure
1/8" NPT
To mains
connection
Unscrew
Fig. 2.5
b) Any conversion required must be performed
by your dealer or a qualified licensed
plumber
or gas service company.
Please provide the service
person
with this
manual before work is started on the range. (Gas conversions are the responsibility
of the dealer or end user.)
c) This range can be used with NATURAL or LP/PROPANE gas. It is shipped
from
the factory adjusted for use with NATURAL gas.
d) Manifold
pressure should be checked with a manometer;
NATURAL gas requires
4.0" W.C.R and LP/PROPANE requires 11.0" W.C.R (see side figure).
Incoming line pressure upstream from the regulator must be 1" W.C.R higher than
the manifold
pressure in order to check the regulator.
The regulator used on this range can withstand
a maximum input pressure of 1/2
PSI (14.0" W.C.P). If the line pressure is in excess of that amount, a step-down
regulator will be required.
e) The appliance,
its individual
shut-off
valve, and pressure
regulator
must
be
disconnected
from the gas supply
piping system
during any pressure testing
of
that system at pressures in excess of 1/2 PSI (3.5 kPa).
f) The appliance
must be isolated from the gas supply piping system by closing its
individual
manual shut-off
valve during
any pressure testing
of the gas supply
piping system at test pressure equal to or less than 1/2 PSI (3.5 kPa).
3. Flexible
Connections:
If local codes
permit,
CSA design-certified,
flexible metal appliance
connector
is
recommended
for connecting this range to the gas supply line. Do Not kink or damage
the flexible connector
when moving the range. The pressure regulator has 1/2" NPT
female pipe threads.You
wilt need to determine
the fittings required,
depending
on
the size of your gas supply line, flexible metal connector
and shutoff valve.
4. Rigid Pipe Connections:
If rigid pipe is used as a gas supply line, a combination
of pipe fittings must be used
to obtain an in-line connection
to the range. All strains must be removed from the
supply and fuel lines so range will be level and in line.
• Use joint compounds
and gaskets
that
are resistant
to action of natural
or
propane gas on all male pipe threads.
• Do not over
tighten
gas fitting
when
attaching
to pressure
regulator.
Over
tightening
may crack regulator.
5. Leak Testing:
IMPORTANT: Leak testing of the appliance
shall be conducted
as follows:
• After
final gas connection
is made, turn
on manual
gas valve and test
all
connections
in gas supply piping and appliance for gas leaks with a soapy water
solution. During this test all appliance
gas valves have to be closed.
• In order to avoid property damage or serious personal injury, never use a lighted
match. If a leak is present, tighten joint or unscrew, apply more joint compound,
tighten again and retest connection
for leak.