Moorwood Vulcan ML60S-HP-D2S Owner's Manual

Medium duty gas steamer–‘h’ version

Advertisement

GAS STEAMER–'H' Version
Manual Part No: 932004-01
Manual Rev
No:
2
MEDIUM DUTY
OWNER'S MANUAL
Click here for

Parts List

MD Gas Steamer
- 1 –

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ML60S-HP-D2S and is the answer not in the manual?

Questions and answers

Summary of Contents for Moorwood Vulcan ML60S-HP-D2S

  • Page 1: Parts List

    MEDIUM DUTY GAS STEAMER–‘H’ Version OWNER’S MANUAL Click here for Parts List Manual Part No: 932004-01 MD Gas Steamer - 1 – Manual Rev...
  • Page 2: Manual Part No

    Country of Destination GB and IE Manual Part No: 932004-01 MD Gas Steamer - 2 – Manual Rev...
  • Page 3: Manual Part No

    Flexible Model No. Product Description Rev. Date Hose Size M-Line Steamer ML60S-HP-D2S 600 Steamer c/w Piezo ignition & 2 Stage Door LH 14/10/05 ½” BSP hose Manual Part No: 932004-01 MD Gas Steamer - 3 – Manual Rev...
  • Page 4: Table Of Contents

    INDEX Page Cover Sheet: Revision Sheet: Index: Introduction: 4 & 5 General Introduction Important Note Specification: 6 - 8 Gas Pressure / Connection Controls Schematic Wiring Diagram Installation: 9 - 11 Important Note Positioning Checking & Commissioning 10 - 11 User’s Instruction: 12 - 14 Important Note...
  • Page 5: Manual Part No

    INTRODUCTION This manual contains all the required information to ensure that your new appliance is installed correctly and that you have all the information necessary to identify and order spare parts. It also contains comprehensive instructions for the user and for cleaning the appliance. To maintain peak performance, it is recommended that the appliance be regularly serviced and that when ordering spare parts, reference be made to the appropriate list quoting the Part No.
  • Page 6: Introduction

    Introduction (cont.) Important Before installing any item please refer to the installation instructions. We recommend that all servicing other than routine cleaning be carried out by our authorised service agents and will accept no responsibility for work carried out by other persons. For satisfactory operation, parts of catering equipment become hot.
  • Page 7: Specification

    SPECIFICATION 600 Gas Steaming Oven Gas Pressure: Natural Gas 15 mbar ( 6” wg.) Propane Gas 37 mbar (14.8” wg.) Connections: ½” BSP Taper Male (Rp ½”) Water 15 mm When connecting using a flexible hose fit a ½” BSP hose Heat Input (Net) Natural Gas Propane Gas...
  • Page 8 Specification (cont.) 600 Gas Steaming Oven Manual Part No: 932004-01 MD Gas Steamer - 8 – Manual Rev...
  • Page 9: Specification

    Specification (cont.) Wiring Diagram THERMOSTAT GAS VALVE THERMOPILE THERMOCOUPLE PILOT TP TH WHITE Manual Part No: 932004-01 MD Gas Steamer - 9 – Manual Rev...
  • Page 10: Installation

    INSTALLATION Important GAS SAFETY REGULATIONS 2000. Your attention is drawn to the latest MUST This appliance be installed by a competent person in accordance with these and any other relevant regulations. Users, too, should be aware of the regulations governing the use of gas appliances, particularly with respect to the need for regular servicing.
  • Page 11 Installation (cont.) Connection to Mains Services: Provide a rigid gas pipe no smaller than the size of steamer inlet connection, together with an NOTE: elbow or other suitable means of connection. - Although rigid pipe is recommended, armoured flexible pipe of a type approved for catering applications may be used. It is also recommended that an easily accessible stop valve be provided adjacent to the appliance.
  • Page 12: Installation

    Installation (cont.) Gas Conversion Before commencing ensure that all external and internal gas/water stop taps are off. Nat Gas to LP Gas: Remove 4 screws securing Bottom Heat Shield, to gain access to Pilot and Injector Elbow. Undo hexagonal nut on pilot and remove injector. Replace with new injector (931767-13) and re-tighten hexagon nut.
  • Page 13: Important Note

    USERS INSTRUCTIONS Important Note! GAS SAFETY (INSTALLATION & USE The attention of the user is drawn to the requirements of the REGULATIONS 2000 MUST . This appliance be used in accordance with those, particularly so in respect of the need for regular servicing. The attention of the user is also drawn to the requirement that those parts, which have been protected by the manufacturer or his agent, are not to be adjusted by the user.
  • Page 14: Operation

    Users Instructions (cont.) Controls Operation: Control Knob - Controls multifunction valve to allow gas to flow to main and pilot burners PILOT marked with “ ”, * “ ” and the flame symbol “ ” positions. Water Taps - Inlet tap controls flow of water into steamer. Drain tap allows water tank to be drained.
  • Page 15: User's Instruction

    Users Instructions (cont.) Opening the Steamer door when hot: IMPORTANT – Do not fully open door when steamer is hot. First, slacken off door handle and allow steam to vent around door opening. Wait at least 1 minute before slowly opening door fully. This precaution prevents a sudden discharge of steam into the operators’...
  • Page 16: Service & Maintenance

    SERVICE AND MAINTENANCE MUST Maintenance only be carried out by a competent person. Ensure that the gas and electricity supply to the appliance has been turned “ ” before dismantling any components. Turn the steamer on and check that the gas pressure at the test point is as stated on the date plate.
  • Page 17 SERVICE AND MAINTENANCE (cont.) Multifunctional Control Valve: Turn off gas supply. Disconnect pilot pipe from valve. Disconnect union fittings from valve inlet & outlet. Transfer gas fittings to new valve and re-fit in reverse order. TESTING Check for gas tightness and test (see “ ”...
  • Page 18 Manual Part No: 932004-01 MD Gas Steamer - 18 – Manual Rev...
  • Page 19: Service & Maintenance

    Service and Maintenance (cont.) Pilot Assembly Turn off gas supply. Remove four screws securing lower heat shield and withdraw shield followed by the three screws fixing the top heat shield. Disconnect thermocouple and thermopile from the pilot bracket. Disconnect pilot pipe from pilot bracket, taking care not to lose pilot injector. Remove nut &...
  • Page 20: Fault Finding

    Service and Maintenance (cont.) Fault Finding Fault Possible Cause Remedy Pilot will not Fault in wires, thermocouple to Check and remake connections establish control valve Faulty thermocouple Replace Pilot flame incorrect Turn up flame if required, clean and adjust as required. Thermocouple incorrectly positioned Re-position as required Explosive Ignition...
  • Page 21: Spare Parts

    SPARE PARTS LIST Part Number Description Quantity 924022-01 Leg Unit 924402-G1 LH Bottom Hinge 924402-04 LH Top Hinge 924402-06 Adjustable Hinge Pin (Top) 924020-03 Door Bush 924432-01 Door Catch Bracket 924863-G3 LH Door Assembly (Lower) 921350-02 Door Handle Extrusion 921315-1 Door Handle Post 924152-G1 Generator Tank Assembly...
  • Page 22 SPARE PARTS LIST Part Number Description Quantity 30000250 ‘O’ Ring 924104-02 Drain Valve JE-DCV Double Check Valve Optional 932129-01 Shelf (Aluminium) Standard 928358-01 Shelves (Stainless Steel) Optional 920515-02 Baskets (Stainless Steel) Optional XC60S-PS Shelf Kit (Aluminium) Optional XC60S-SS Shelf Kit (Stainless Steel) Optional XC60S-SB Basket Accessory Kit (Stainless Steel)
  • Page 23 VISCOUNT CATERING LIMITED The Company offer twelve months warranty with each new piece of equipment subject to our normal conditions of sale and will undertake responsibility for warranty subject to the additional following conditions. Notice of the defect/damage is given within 48 hours of breakdown or in the case of damage four days from the date of despatch and the manufacturer given adequate opportunity to examine the goods in order that appropriate action can be taken.
  • Page 24: Manual Part No: 932004-01 Md Gas Steamer

    Manual Part No: 932004-01 MD Gas Steamer - 24 – Manual Rev...

Table of Contents