Mitsubishi Electric PEAD-RP-EA Installation Manual

Hide thumbs Also See for PEAD-RP-EA:

Advertisement

Air-Conditioners
PEAD-RP·EA (2)
PEAD-RP·GA
PEHD-P·EAH

INSTALLATION MANUAL

For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing
the air-conditioner unit.
INSTALLATIONSHANDBUCH
Aus Sicherheitsgründen und zur richtigen Anwendung vor Installation der Klimaanlage die vorliegende Bedie-
nungsanleitung und das Installationshandbuch gründlich durchlesen.
MANUEL D'INSTALLATION
Avant d'installer le climatiseur, lire attentivement ce manuel, ainsi que le manuel d'installation de l'appareil
extérieur pour une utilisation sûre et correct.
INSTALLATIEHANDLEIDING
Lees deze handleiding en de installatiehandleiding van het buitenapparaat zorgvuldig door voordat u met het
installeren van de airconditioner begint.
MANUAL DE INSTALACIÓN
Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de
aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, prima di installare il condizionatore d'aria leggere attentamente il presente
manuale ed il manuale d'installazione dell'unità esterna.
E°XEIPI¢IO O¢H°IøN E°KATA™TA™H™
°È· ÛˆÛÙ‹ Î·È ·ÛÊ·Ï‹ ¯Ú‹ÛË, ‰È·‚¿ÛÙ ÚÔÛÂÎÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ, ηıÒ˜ Î·È ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ
ÂÁηٿÛÙ·Û˘ Ù˘ Â͈ÙÂÚÈ΋˜ ÌÔÓ¿‰·˜, ÚÈÓ ·fi ÙËÓ ÂÁηٿÛÙ·ÛË Ù˘ ÌÔÓ¿‰·˜ ÎÏÈÌ·ÙÈÛÙÈÎÔ‡.
MANUAL DE INSTALAÇÃO
Para uma utilização segura e correcta, leia atentamente este manual e o manual de instalação da unidade
exterior antes de instalar o aparelho de ar condicionado.
INSTALLATIONSMANUAL
Læs af sikkerhedshensyn denne manual samt manualen til installation af udendørsenheden grundigt, før du
installerer klimaanlægget.
INSTALLATIONSMANUAL
Läs bruksanvisningen och utomhusenhetens installationshandbok noga innan luftkonditioneringen installeras så
att den används på ett säkert och korrekt sätt.
MONTAJ ELK‹TABI
Emniyetli ve do¤ru kullanım için, klima cihazını monte etmeden önce bu kılavuzu ve dıfl ünite montaj kılavuzunu
tamamıyla okuyun.
РУКОВОДСТВО ПО УСТАНОВКЕ
Для обеспечения безопасной и надлежащей эксплуатации внимательно прочтите данное руководство и
руководство по установке наружного прибора перед установкой кондиционера.
FOR INSTALLER
FÜR INSTALLATEURE
POUR L'INSTALLATEUR
VOOR DE INSTALLATEUR
PARA EL INSTALADOR
PER L'INSTALLATORE
°π∞ ∞À∆√¡ ¶√À ∫∞¡∂π ∆∏¡ ∂°∫∞∆∞™∆∞™∏
PARA O INSTALADOR
TIL INSTALLATØREN
FÖR INSTALLATÖREN
MONTÖR ‹Ç‹N
ДЛЯ УСТАНОВИТЕЛЯ
English
Deutsch
Français
Nederlands
Español
Italiano
∂ÏÏËÓÈο
Português
Dansk
Svenska
Türkçe
Русский

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric PEAD-RP-EA

  • Page 1: Installation Manual

    Air-Conditioners PEAD-RP·EA (2) PEAD-RP·GA PEHD-P·EAH INSTALLATION MANUAL FOR INSTALLER English For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing the air-conditioner unit. INSTALLATIONSHANDBUCH FÜR INSTALLATEURE Deutsch Aus Sicherheitsgründen und zur richtigen Anwendung vor Installation der Klimaanlage die vorliegende Bedie- nungsanleitung und das Installationshandbuch gründlich durchlesen.
  • Page 2 Fig. 2-1 (mm) Fig. 3-1 Fig. 3-2 (mm) Fig. 4-1...
  • Page 3 (mm) 45°±2° Fig. 5-2 Fig. 5-1 <A> In case of RP·EA (2) Fig. 6-1 <B> In case of RP·GA <C> In case of P·EAH Fig. 7-1 Fig. 7-2...
  • Page 4 (mm) B-1. B-2. Fig. 7-3 TEMP. ON/OFF MENU ON/OFF FILTER BACK MONITOR/SET CHECK TEST PAR-21MAA CLOCK OPERATION CLEAR Fig. 7-4 Fig. 7-5...
  • Page 5 <A> In case of rear inlet Fig. 8-2 <B> In case of bottom inlet Fig. 8-1 TEST RUN COOL, HEAT ˚C ˚C SIMPLE ERROR CODE TEMP. ON/OFF TEMP. ON/OFF MENU ON/OFF FILTER BACK MONITOR/SET CHECK TEST MENU ON/OFF FILTER OPERATION PAR-21MAA CLOCK CLEAR...
  • Page 6: Table Of Contents

    • Do not operate the air conditioner without the air filter set in place. If the air • Use only accessories authorized by Mitsubishi Electric and ask a dealer or filter is not installed, dust may accumulate and breakdown may result.
  • Page 7: Installing The Indoor Unit

    3. Installing the indoor unit 4. Installing the pipes 5. Refrigerant piping work 3.1. Check the indoor unit accessories (Fig. 3-1) 5.1. Refrigerant and drainage piping connection (Fig. The indoor unit should be supplied with the following accessories. 5-1) • When commercially available copper pipes are used, wrap liquid and gas pipes Accessory name Q’ty with commercially available insulation materials (heat-resistant to 100 °C or more,...
  • Page 8: Drainage Piping Work

    5. Refrigerant piping work 6. Drainage piping work 7. Electrical work • After connecting the refrigerant piping to the indoor unit, be sure to test the pipe <For models with heater> connections for gas leakage with nitrogen gas. (Check that there is no leakage from the refrigerant piping to the indoor unit.) 5.3.
  • Page 9: Remote Controller

    7. Electrical work *1. A breaker with at least 3 mm contact separation in each pole shall be provided. Use non-fuse If the indoor and outdoor units have separate power supplies, refer to the table at the breaker (NF) or earth leakage breaker (NV). below.
  • Page 10: Function Settings

    7. Electrical work 7.3. Function settings 7.3.1. For wired remote controller (Fig. 7-5) ⁄ Mode number ⁄ Setting number ⁄ Refrigerant address ⁄ Unit number Changing the power voltage setting • Be sure to change the power voltage setting depending on the voltage used. 1 Go to the function setting mode.
  • Page 11: Duct Work

    8. Duct work 9. Test run Duct work 9.1. Before test run s After completing installation of the wiring and piping of the indoor and out- • Connect canvas duct between unit and duct. (Fig. 8-1) • Use incombustible material for duct parts. door units, check for refrigerant leakage, looseness in the power supply or •...
  • Page 12 9. Test run [Output pattern A] Errors detected by indoor unit Wired remote Wireless remote controller controller Beeper sounds/OPERATION Symptom Remark INDICATOR lamp flashes Check code (Number of times) Intake sensor error P2, P9 Pipe (Liquid or 2-phase pipe) sensor error E6, E7 Indoor/outdoor unit communication error Drain sensor error...
  • Page 13: System Controll

    9. Test run Note: Operation is not possible for about 30 seconds after cancellation of function selection. (Correct operation) For description of each LED (LED1, 2, 3) provided on the indoor controller, refer to the following table. LED 1 (power for microcomputer) Indicates whether control power is supplied.
  • Page 14 This product is designed and intended for use in the residential, commercial and light-industrial environment. • Low Voltage Directive 73/23/ EEC The product at hand is • Electromagnetic Compatibility Directive 89/ based on the following EU regulations: 336/ EEC Please be sure to put the contact address/telephone number on this manual before handing it to the customer.

This manual is also suitable for:

Pead-rp-gaPehd-p-eah

Table of Contents