Honeywell RTH1100 Quick Installation Manual page 21

Non-programmable thermostat
Hide thumbs Also See for RTH1100:
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting
Heating or
cooling sys-
tem does not
respond
or
is flashing
Move SYSTEM switch to set
system to Heat. Make sure the
temperature is set higher than
the Inside temperature.
Move SYSTEM switch to set
system to Cool. Make sure the
temperature is set lower than
the Inside temperature.
Check circuit breaker and reset
if necessary.
Make sure power switch at
heating & cooling system is on.
Make sure furnace door is
closed securely.
Wait 5 minutes for the system to
respond.
Compressor protection feature
is engaged. Wait 5 minutes
for the system to restart
safely, without damage to the
compressor.
19
RTH1100
69-2446EF—01

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents