Starting up and operation
Indicator on Fujitsu battery unit (FJBU)
Figure 14: Indicator on FJBU
1
Indicator on FJBU (two colors)
Flashes green when the battery unit is charging.
Flashes slowly green when the battery unit is discharging.
Lights up green when the battery unit is fully charged.
Flashes orange in case of capacity alarm or temperature alarm.
Lights up orange in case of general battery failure.
6.1.3

Indicators of the hot-plug system fans

A fan status indicator (LED on the system board) is assigned to each system
fan. The status indicators are not visible unless the housing is open. The
respective LED is set with commands in Server Management.
LED
lights orange
70
Meaning
Possible fan failure (rotation speed less than 70% of the
original speed) or fan failure
Operating Manual