Panasonic WH-MDF09C3E5 Installation Manual page 61

Hide thumbs Also See for WH-MDF09C3E5:
Table of Contents

Advertisement

Terminals
Connection
Solar pump
22 to 23
station
Solar 3-way
19 to 21
directional valve
Ext . control sig-
17 to 18
nal
Temperature
15 to 16
sensor for hot-
water tank
Temperature
13 to 14
limit switch for
hot-water tank
Room
9 to 12
thermostat
Electric immer-
Mass
sion heater for
to 8
hot-water tank
3-way directional
4 to 6
valve
2-way directional
1 to 3
valve
Terminal strip and table of inputs and outputs with functions
Aquarea air/water heat pump – Installation manual for monobloc and split systems C, D and E series 05 / 2014
Function
Input of the ON signal
from solar pump 2 (230 V AC)
Output for triggering
the solar 3-way directional
valve
Input for external control sig-
nal, volt-free, normally closed
Input for temperature sensor
of the hot-water tank
Input for temperature limit
switch of the hot-water tank
Input for external room
thermostat
230 V output for activating /
deactivating the electric im-
mersion heater for hot-water
storage tanks
230 V output for control of the
3-way directional valve (e .g .
for heating, hot-water tank)
230 V output for controlling
the 2-way directional valve
(e .g . for floor heating, cooling)
Inputs and outputs (external interfaces)
Comments
Use additional circuit board CZ-NS1P, CZ-NS2P
or CZ-NS3P
Connect the 3-way directional valve
so that it prevents flow through the
solar circuit and heat exchanger of
the hot-water tank when closed .
These two terminals are jumpered
on delivery . Connection:
1-pin (min . 3 mm contact clearance)
When the contacts are open, the device is switched
off and the remote control is disabled .
The jumper between terminal 17 and 18 must be
removed, if the external control device (optional) is
connected to the hydro module . The max . operating
current of the control device must be less than 3 A
Use an NTC sensor
Terminals 13 / 14 must be jumpered if no temperature
limit switch is used for the hot-water tank
For exclusive control of heating
mode via the external room thermo-
stat, only phases L and L1 are con-
nected to the terminal strip .
This also applies for devices without a cooling
function . This connections do not permit switching
between heating and cooling mode .
Condition
L/L1
Room temperature >
Circuit open
Target temperature
(heating off)
Room temperature <
Circuit closed
Target temperature
(heating on)
Operating mode
Heating
heat pump
The maximum output capacity of the electric immer-
sion heater for hot-water storage tanks should not
exceed 3 kW
Hot-water tank
AB
A
B
Heating circuit
Connection on automatic deactivation
of heating circuits in cooling mode
via a 2-way directional valve
Top: Motorised 2-way directional valve
Bottom: Spring-loaded 2-way
directional valve, normally open
Electrical installation
Number
Cable
2
3
OPEN
CLOSE
N
2
.
ms
2
2
4
HEAT
COOL
N
L
L/L 2
Circuit closed
(cooling on)
Circuit open
(cooling off)
Cooling
3
3
N
OPEN (AB -> A)
CLOSE (AB -> B)
N
3
OPEN
CLOSE
N
OPEN
CLOSE
8 – 61