Aquarea air/water heat pump – Installation manual for monobloc and split systems C, D and E series 05 / 2014
Open the hydro module as described in section 5 .2 .
Use cables compliant with 60245 IEC 57 or thicker for the mains
connections .
Pass the cables through the cable glands at the underside of the unit .
Connect the mains connection cables as shown in the figures .
Ensure that the earthing cable is slightly longer than the other cables .
Connect the connecting cables to the outdoor unit as shown in the
figures . Ensure that the earthing cable is slightly longer than the other
cables .
Use the strain reliefs to secure the mains connection cables .
Connect the mains connection cable to the electricity mains .
Use the following fuses to protect the individual mains connections
(isolating distance between the pins at least 3 .0 mm each):
Mains connection 1
30 A
20 A
30 A
Electrical installation
Fuse
Mains connection 2
Mains connection 3
30 A
16 A
30 A
Mains connections
Split systems
8
16 A
16 A
8 – 59