en | Install the MIC (standard) PSU
Notice!
To maintain the IP rating of the power supply enclosure, install only listed or recognized
conduit hubs or fittings with the same environmental rating as the enclosure in compliance
with the installation instruction of the hub or fitting.
Notice!
Refer to the MIC Series Power Supply Installation Manual included with the PSU for full details
on installing a MIC Series PSU and connecting to a MIC Camera.
To install the power supply unit (PSU), follow these steps:
1. Select a secure installation location for the PSU. Ideally, this is a location where the device
cannot be interfered with either intentionally or accidentally.
Bosch recommends using an environmentally suitable, lockable equipment cabinet.
2. Loosen the four (4) captive Phillips head screws on the top of the lid of the power supply
enclosure. Lift the lid and set it upside down next to the enclosure.
Notice!
Do not stretch or cut, or otherwise disturb, the earth core cable (shown in the figure below)
to the inside of the lid and to the earth termination post.
3. Locate the four (4) mounting holes of the power supply enclosure.
Figure 5.5: Holes for screws for mounting enclosure mounting; holes for screws for enclosure lid
Number
1
2
4. Drill four (4) holes in the mounting surface for the mounting anchors appropriate for M6
screws (not supplied).
5. Secure the enclosure to the mounting surface using four (4) M6 stainless steel screws and
washers (not supplied), which fit through the large holes in the enclosure.
Notice!
If you are securing the power supply enclosure in a vertical position (for example, on a wall),
one person should hold the enclosure lid while another secures the enclosure body in place,
to avoid damage to any part of the enclosure, and/or injury to the installer(s).
6. Unscrew the two (2) M3 screws on the internal high voltage input head-end shield (marked
with "Danger") covering the mains cable terminal HD1; retain the screws.
2016.03 | 2.1 | F.01U.249.416
Description
Hole for mounting screw in enclosure
Hole for lid screw in enclosure