Safety Devices - Fujitsu ASU9RLS3 Design & Technical Manual

Hide thumbs Also See for ASU9RLS3:
Table of Contents

Advertisement

10.

SAFETY DEVICES

Circuit protection
Fan motor protection
Compressor protection
Protection form
Current fuse
(NEAR THE TERMINAL)
Current fuse
(MAIN PRINTED CIRCUIT
BOARD)
Current fuse
(FILTER PRINTED
CIRCUIT BOARD)
Thermal protection
program
Thermal protection
program
(Discharge temp.)
- (02 - 15) -
Model
AOU9RLS3H
AOU12RLS3H
250V 20A
250V 5A
250V 15A
250V 3.15A
-
OFF : 212±27 °F (100±15 °C)
ON : 203±18 °F (95±10 °C)
OFF : 230 °F (110 °C)
ON : After 7 minutes
AOU15RLS3H
250V 5A
250V 3.15A
250V 5A
250V 25A
250V 5A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Asu12rls3Aou9rls3hAou12rls3hAou15rls3hAsu15rls3

Table of Contents