Goldline AsDC-W Operating And Assembly Manual page 12

Electric tankless water heater for central heating systems

Advertisement

12
Ad. A4. „SETTINGS – PID-P" –
- press 1 time, SETTINGS sign appears
- press 2 times, PID-P sign appears
(
to enter press three times button on the right
- press another time, PID-P function is visible
- change parameter
- change parameter's value
ATTENTION:
In case boiler needs long time to achieve set temperature - set 4 or 5
In case boiler reaches set temperature to quickly – set 1 or 2
- „BACK" (given parameters are set)
Multiple press enables getting back to main menu
Ad. A5. „SETTINGS – CH HISTERESE"
- press 1 time, SETTING sign appears
- press 2 times, CH HISTERESE sign appears
(
to enter press four times button on the right)
- press another time, below screen is visible
CH HISTERESE
- decrease histerese 1 – 2 – 3 – 4 - 5
- increase histerese 2 – 3 – 4 – 5 – 6
- „BACK" (given parameters are set)
Multiple press enables getting back to main menu
proportional integral derivative controller
SETTINGS
ad. A4
SETTINGS
ENERGY CONSUM.
VENTING
)
POWER
SECTIONS
DATE & TIME
PID-P
CH HISTERESE
PID-P
DEFAULT: 2
ad. A5
SETTINGS
ENERGY CONSUM.
VENTING
6
POWER
SECTIONS
DATE & TIME
PID-P
CH HISTERESE
CH HISTERESE
DEFAULT: 4
66
1
2
66
1
2