Yamaha RX-V465 Service Manual page 52

Av receiver/av amplifier
Hide thumbs Also See for RX-V465:
Table of Contents

Advertisement

RX-V465/HTR-6240/AX-V465
DC/TH
DC:
Power amplifier DC (DC voltage) output is
detected.
Normal value:
TH:
Temperature on the heat sink is detected.
Normal value:
If DC and TH are out of the normal value
*
range, the protection function works to turn
off the power.
IMP/PL
IMP:
8 or 6 ohms impedance setup detection
IMP 8:
IMP 6:
PL:
PLDET (Power amplifier output voltage detection)
The power amplifier output voltage is detected
and the power amplifier input voltage is controlled
according to the detected output voltage.
(Reference voltage: 3.3V=255)
U, C, T, K, A, B, G, E, F models (Reference voltage: 3.3 V=255)
PLDET (8 ohms/6 ohms)
LIM (Limiter control)
R, L models (Reference voltage: 3.3 V=255)
PLDET (8 ohms/6 ohms)
LIM (Limiter control)
J model(基準電圧:3.3 V = 255)
PLDET(8 ohms/6 ohms)
LIM(リミッター制御)
52
23 to 70
(Reference voltage: 3.3 V=255)
0 to 124
(Reference voltage: 3.3 V=255)
D C : 0 4 6 T H : 1 1 1
8 ohm setting
6 ohm setting
I M P : 8
During normal operation
255 / 255
H
During normal operation
255 / 255
H
通常値
255 / 255
H
DC/TH
DC:
パワーアンプ DC(直流電圧)出力の検出
正常値:
23 ∼ 70
(基準電圧:3.3 V = 255)
TH:
ヒートシンク温度の検出
正常値:
0 ∼ 124
(基準電圧:3.3 V = 255)
※ DC および TH は正常値を外れるとプロテク
ションが働き、電源が切れます。
TH/PL
IMP: インピーダンス設定の検出
(このモデルには適用されません。 )
PL:
PLDET(パワーアンプ出力電圧の検出)
パワーアンプ出力電圧を検出して、パワーアンプ
入力電圧を制御します。
(基準電圧:3.3 V = 255)
P L : 2 5 5
Value for starting limiter operation
87 / 146
L
Value for starting limiter operation
100 / 100
L
リミッタ動作開始値
100 / 100
L
Value for canceling limiter operation
125 / 171
H
Value for canceling limiter operation
131 / 131
H
リミッタ動作解除値
131 / 131
H