Outside air intake

For this equipment combustion air can also be added from the outside. It makes installation easier
in houses with passive and low energy consumption if the ventilation in the living quarters is
controlled. Connection is possible through a tube with a diameter of 100 mm. The combustion air
supply pipe has to be equipped with a stop-cock close to the stove. Of course, heating is also
possible with the air of the room – see: Item 2.2 (Germany).
The stoves use room air for combustion, and a sufficient supply of combustion air is therefore
essential. The air pressure in the room of installation must not be negative. Please observe the
relevant technical rules / regulations and any additional information when operating your appliance
in combination with air conditioning systems (for ex. ventilation systems, exhauster hoods,
pneumatic conveyor systems etc.).
Outside air intake Ø 98mm
12 <
<
<
<