3- Fitting and putting into service of the heat pump

3-1 Rules of establishment:

Many measures define the place of the appliance;
Electric and hydraulic connections must be carried out according to national wiring regulation.
The appliance must be installed outside.
The appliance must be put on its antivibratory studs, regulated with horizontal and on a massive base (concrete
stone or steel frame);
the appliance;
connection collecting the condensates.
The obstacles such as wall and vegetation must be separated from the apparatus as indicated on the diagram
below.
The ventilator should not blow towards the windows or crossing place.
There must be more than 1.5M space on the top of the unit.
The fixing board of the unit must be fixed by bracket.
Connect drainpipe to the outlet of condensate water, then draw the drainpipe into blowoff pipe.
Other precautions of establishment:
- Do not install the appliance near a way with circulation of cars in order to avoid mud projections.
- Avoid directing blowing counters the dominant winds.
- If the appliance is intended to be used in period winter, put it at the shelter of the falls of snow.
- The appliance must be able to be watch on especially so that children do not play around.
When install pipeline for heat pump, user need to install an additional pressure reducing valve
(working pressure is less or equal to 3bar) in the water inlet pipe, for pressure reduction
this base must have a sufficient height to prevent entering of water by the bottom of
to regulate the height with the studs so as to be able to connect the
Attention:
and pressure stabilizing in the water supply system.
9
it is essential to respect them:
0.5m
UNIT
0.5m
0.5m
0.5m