Tunstall CPA6 Installation & User Manual

Multizone alarm control panel

Advertisement

Quick Links

CPA6
Installation & User Guide
Compatible Equipment
CPA6 OM - Output Module
9040 - Loudspeaker
DC54/58 - Digital Communicators (Stand Alone Only)
1 of 16
496524 Issue A
CPA6

Advertisement

Table of Contents
loading

Summary of Contents for Tunstall CPA6

  • Page 1 CPA6 Installation & User Guide Compatible Equipment CPA6 OM - Output Module 9040 - Loudspeaker DC54/58 - Digital Communicators (Stand Alone Only) 1 of 16 496524 Issue A CPA6...
  • Page 2: Event Memory

    CPA6 Overview Introduction Facilities The CPA6 multizone alarm control panel has been The panel offers the following facilities as standard:- manufactured under exacting quality control INPUTS standards and incorporates the latest proven electronic technology and high quality components to assure outstanding and lasting performance.
  • Page 3: Circuit Types

    NOTE: During setting, if either of the two devices Each contact must have a 4k7 shunt resistor fitted to connected to this type of circuit is operated, then a enable the CPA6 to continuously monitor the circuit fault condition will occur, which will inhibit the system wiring.
  • Page 4 Detection Zones and Zone Expansion signalling purposes following activation of any P.A. circuit. (The CPA6 has six zones. Each zone may have one ALARM circuit only, or can, by the addition of external Zone This drives high (to + 12V via a 47R resistor) for Expansion Modules, (Z.E.M.’s) be expanded in...
  • Page 5: Zone Wiring

    CPA6 Zone Wiring NOTE: Up to five Z.E.M.’s may be fitted to zone of the CPA6, to provide a maximum of ten individually controlled/indicated detection circuits per zone. N.C. Detector Correct polarity and orientation must be 4K7 contact contact & tamper 2-wire configuration observed when connecting Z.E.M.’s...
  • Page 6: Output Table

    CPA6 Output Table TABLE 1 PANEL STATUS CIRCUIT “OPEN” “TEST” “EXIT” “SET” “ENTRY” TYPE 24Hr/Fault 24Hr/Fault 24Hr/Fault Main Alarm Main Alarm TYPE 0 TAMPER ONLY Fault Fault Fault Main Main CIRCUIT Audible (L) Audible (L) Audible (L) Audible (L) Audible (L)
  • Page 7 SCAN FAULT Loading Defaults “SCAN FAULT” will be logged if the CPA6 cannot sensibly ascertain the status of any detection circuit for a period of three scan cycles. Power down panel mains and battery.
  • Page 8: Operation

    CPA6 STEP KEYPAD DISPLAY KEYPAD Comments OPERATION READOUT OPERATION Clock/calendar starts timing from midnight on January 1st. when power is first applied to the panel. “01 Jan. 00:00:00” Code places panel in the ‘Engineer Routine’. At this stage, no events are stored in the log: pressing the “YES/ENTER”...
  • Page 9 CPA6 STEP KEYPAD DISPLAY KEYPAD Comments OPERATION READOUT OPERATION Skips the Zone and Circuit setting routine and steps the panel to the next stage of commissioning. “NO” Initiates the Zone and Circuit setting routine. NOTE: At this point the control panel tests all Zone wiring for short-circuits and “YES/ENTER”...
  • Page 10 CPA6 STEP KEYPAD DISPLAY KEYPAD Comments OPERATION READOUT OPERATION The display asks for confirmation of the circuit type that has been entered on the keypad for the last detection circuit of the alarm system: i.e Zone 6, Circuit xx. “Confirm that:- Zone 6 Confirms Zone 6.
  • Page 11 CPA6 STEP KEYPAD DISPLAY KEYPAD Comments OPERATION READOUT OPERATION Enters the required method of ‘SETTlNG" and “OPENING” control (shunt-Lock or Auto. Ex/En.) into memory and initiates the next step of Commissioning. The display awaits information. Timed exit may be applied to the system regardless of the access method used.
  • Page 12 CPA6 STEP KEYPAD DISPLAY KEYPAD Comments OPERATION READOUT OPERATION KEY-IN MAIN ALARM SOUNDER As keys are pressed, the display will show the sounder duration time DURATION IN being set in seconds. When the displayed time is correct, press the SECONDS “YES/ENTER key.
  • Page 13 CPA6 STEP KEYPAD DISPLAY KEYPAD Comments OPERATION READOUT OPERATION The display awaits keypad information. ENTER USER NUMBER TO BE As keys are pressed, the display will show the code being set. When this is correct, press the “YES/ENTER” key. PROGRAMMED “Code X? 0000”...
  • Page 14 CPA6 TO PART SET THE SYSTEM (Only if this facility has User Operating Instructions been programmed) TO SET THE SYSTEM Ensure that all monitored areas, except those to (Part Set facility not programmed) be shunted (excluded), are secured; 1. Ensure that all monitored areas are secured The panel display should show the date and time 2.
  • Page 15: Tamper Alarm

    CPA6 Tamper Alarm Testing A Tamper Alarm will occur if any of the intruder Two forms of testing are available and these are system equipment or cables are interfered with the Bell Test and the Walk Test; or damaged; The panel should show the date and time and If the panel is Set a full alarm will occur, to unset the ‘System Open’;...
  • Page 16 CPA6 This page intentionally left blank 16 of 16 CPA6 496524 Issue A...