B. Clearances
WARNING! Risk of Fire!
You must comply with all minimum air space clearances
to combustibles as specified in Figure 3.2. DO NOT pack
required air spaces with insulation or other materials.
Framing or finishing material used on the front of, or in
front of, the fireplace closer than the minimums listed must
be constructed entirely of non-combustible materials (i.e.,
steel studs, concrete board, etc.). Failure to comply may
cause fire.
Figure 3.2
Clearances to Combustible Materials
10
Heatilator • CL36D, CR36D Installation Manual • 4012-046 • Rev D • 10/03/13
Storm Collar
Roof Flashing
(attic)
(insulation)
2 in. (51 mm) min.
Ceiling Firestop
0 in.
to floor

Minimum Clearances to Combustibles

WITHIN ENCLOSURE AREA
Fireplace to backwall
Fireplace to sidewall
Top standoffs to header
Door opening to sidewall
MANTEL
Mantel minimum height
Maximum mantel depth
Shaded areas
represent
2 in. (51 mm) min.
air space clearance
required around pipe
Attic
Insulation
Shield
(ceiling)
Offset/Return (secured
with hanger straps)
(ceiling)
Must have 2 in. (51 mm)
minimum clearance
to header
Chimney air kit
attached here (not shown)
0 in. to level
of standoffs
Note: Chimney air kit is not
shown, but is required in Canada.
1/2 in. (13 mm) to back &
side of appliance
1/2 in. (13 mm)
1/2 in. (13 mm)
0 in. (0 mm)
18 in. (457 mm)
41 in. (1041 mm)
12 in. (305 mm)