I. COMPONENT IDENTIFICATION
6
3
4
25
2
1
27
29
26
17
18
24
23
Upflow/Horizontal
1
Gas Valve
2
Gas Line Entrance (Alternate)
3
Combustion Air Intake Connection / "Coupling"
4
Hot Surface Igniter
5
Burners
6
Rollout Limit
7
Flame Sensor
8
Flue Pipe Connection / "Coupling"
9
Flue Pipe (Internal)
10 Primary Limit
11 Pressure Switch
12 Gas Line Entrance
13 Rubber Elbow
14 Flue Pipe Connection (Alternate)
15 Induced Draft Blower
16 Electrical Connection Inlets (Alternate)
17 Coil Front Cover Drain Port
18 Drain Line Penetrations
19 Blower Door Interlock Switch
20 24-Volt Thermostat Connections
21 Integrated Control Module
(with fuse and diagnostic LED)
22 Transformer (40 VA)
23 Circulator Blower
6
7
5
8
10
11
12
13
14
15
17
18
19
20
21
22
24 Auxiliary Limit
25 Gas Manifold
26 Junction Box
27 Coil Front Cover
28 Drain Trap
29 Electrical Connection Inlets
9
II. SAFETY CONSIDERATIONS
Adhere to the following warnings and cautions when installing, adjust-
ing, altering, servicing, or operating the furnace. To ensure proper
installation and operation, thoroughly read this manual for specifics
pertaining to the installation and application of this product.
This furnace is manufactured for use with natural gas. It may be field
converted to operate on L.P. gas by using the appropriate L.P. conver-
sion kit listed in the PROPANE GAS/HIGH ALTITUDE INSTALLA-
16
TIONS section of this manual
Install this furnace only in a location and position as specified in LO-
CATION REQUIREMENTS & CONSIDERATIONS section and IN-
STALLATION POSITIONS section of this manual.
Provide adequate combustion and ventilation air to the furnace as
28
specified in COMBUSTION & VENTILATION AIR REQUIREMENTS
section of this manual.
Combustion products must be discharged to the outdoors. Connect
this furnace to an approved vent system only, as specified in VENT/
FLUE PIPE & COMBUSTION AIR PIPE section of this manual.
Never test for gas leaks with an open flame. Use a commercially avail-
able soap solution made specifically for the detection of leaks to check
all connections, as specified in GAS SUPPLY AND PIPING section of
this manual.
Always install a furnace to operate within the furnace's intended tem-
perature-rise range with a duct system which has external static pres-
sure within the allowable range, as specified on the furnace rating plate
and OPERATIONAL CHECKS section of these instructions.
When a furnace is installed so that supply ducts carry air circulated by
the furnace to areas outside the space containing the furnace, the
return air shall also be handled by duct(s) sealed to the furnace casing
and terminating outside the space containing the furnace.
A gas-fired furnace for installation in a residential garage must be in-
stalled as specified in the LOCATION REQUIREMENTS AND CON-
SIDERATIONS section of this manual.
This furnace may be used as a construction site heater only if certain
conditions are met. These conditions are listed in the PRODUCT
APPLICATION section of this manual.
T
O PREVENT PERSONAL INJURY OR DEATH DUE TO IMPROPER
,
INSTALLATION
ADJUSTMENT
,
MAINTENANCE
REFER TO THIS MANUAL
ASSISTANCE OR INFORMATION
SERVICE AGENCY OR THE GAS SUPPLIER
T
HIS PRODUCT CONTAINS OR PRODUCES A CHEMICAL OR CHEMICALS
WHICH MAY CAUSE SERIOUS ILLNESS OR DEATH AND WHICH ARE
S
KNOWN TO THE
TATE OF
DEFECTS OR OTHER REPRODUCTIVE HARM
HIGH VOLTAGE!
T
O AVOID PROPERTY DAMAGE
DEATH DUE TO ELECTRICAL SHOCK
BE LOCATED TO PROTECT THE ELECTRICAL
COMPONENTS FROM WATER
5
WARNING
,
,
ALTERATION
SERVICE OR
. F
OR ADDITIONAL
,
CONSULT A QUALIFIED INSTALLER
.
C
ALIFORNIA TO CAUSE CANCER
.
WARNING
,
PERSONAL INJURY OR
,
THE FURNACE MUST
.
,
,
BIRTH

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents