8.4 Operation Modes and Functions

8.4.1 Fan mode
( 1) Outdoor fan and compressor stop.
(2) Temperature setting function is disabled, and no setting temperature is displayed.
(3) Indoor fan can be set to high/med/low/auto.
(4) The louver operates same as in cooling mode.
(5) Auto fan:
For TAS-09EHN, TAS-12EHN, TAS-18EHN models:
T1-24
For TAS-24EHN model:
8.4.2 Cooling Mode
8.4.2.1 Compressor running rules
The maximum operation frequency of compressor after starting submits to following rule.
6.0
a
5.0
b
4.0
c
2.5
d
1.0
e
27.5
27
25.5
25
H
(H-L)*0.75+L
(H-L)*0.5+L
(H-L)*0.25+L
L
High
Medium
Low