SERVICE MODE

A. Market / Region SETUP
In the initial condition for this model, Market and Region
information are undefined.
In the following cases, be sure to set up Market/Region.
1. When updating the system using CD-R
(Part code :0PRADC7123--A ).
2. When replacing a DVD main p.w.board.
B. How to enter Service Mode.
You can enter Service Mode in any one of the following ways
1. Displaying Internal Setup screen
1-1. Dislay on "No Disc" by Function button.
1-2. Press the remote key and step by step enter 7-2-2-4-
stop button , then speedy press NEXT
appear about the figure A picture on TV screen.
2. Setting Market code
2-1. While a highlighted indicator is displayed on the figure
A of the Market denotation , push
the remote controller.
The indicator reset to "WM".
Market code of this model is "XE".
2-2. Specify the code of the model in accordance with the
Market/Region setup above.
2-3. Once the desired code is display , push p button to
move the highlighted indicator to the Region input
area.
3. Setting REGION code
3.1 While a highlighted indicator is displayed on about the
figure B of the Region denotation, push ENT,
each button on the remote controller. With each push
the indicator will advance as shown below.
1 <-> 2 <-> 3 <-> 4 <-> 5 <-> 6
3.2 Set up the region coder currently displayed on the
set.
3.3 Once the desired number is displayed, push p button
to move the highlighted indicator to Exit area.
4. Saving settings
4.1 Make sure that the Market and Region settings are
properly set.
(If any of the settings are incorrect, you can make a
change by moving the indicator using o button, and
following procedures 2 and 3 above. )
4.2 After ensuring that the settings are all correct, push
ENT button while the indicator is on Exit area. The
settings are now saved.
5. Power OFF.
MARKET
MARKET
MARKET
REGION
REGION
REGION
Exit
Exit
Exit
button,
MARKET
or
button on
REGION
Exit
and
MARKET
REGION
Exit
- 4 -
WM
WM
1
1
1
Figure A
WM
1
Figure B
3
The sample of a display of a region
code.
WM
1
Figure C
(Reference figure)
(Reference figure)
(Reference figure)

Advertisement