Troubleshooting Suggestions - Wells SC7 Operation Manual

Soup cookers and cook ’n hold warmers
Hide thumbs Also See for SC7:
Table of Contents

Advertisement

SYMPTOM
No power to warmer
Warmer will not heat
Warmer trips circuit breaker
Warmer slow to heat
There are no user-serviceable components in this appliance.
In all instances of damage or malfunction, contact your Authorized Wells Service Agency for repairs.
TROUBLE SHOOTING SUGGESTIONS
POSSIBLE CAUSE
Circuit breaker off or tripped
Unit not plugged in
Temperature control not set
Internal damage
Wet insulation
Pan leaking or other internal
damage
Internal damage
Mineral deposits on pan acting
as a insulator
Connected to wrong voltage
Too much water in pan
9
SUGGESTED REMEDY
Reset circuit breaker
Make sure unit is plugged in to
power receptacle
Set control to desired
temperature
Contact you Authorized Wells
Service Agency for repairs
Allow to dry or replace insulation
Contact your Authorized Wells
Service Agency for repairs
Contact your Authorized Wells
Service Agency for repairs
Clean pan(s) with delime
cleaner. DO NOT USE ON
ALUMINUM SURFACES!
Verify supply voltage (must
match voltage on warmer
nameplate)
Remove water from pan until 1"
of water remains in pan