HUMIDIFICATION AND DE-HUMIDIFICATION SETPOINTS
DE-HUMIDIFY:
Allows you to reduce and maintain the relative humidity to a specific
setpoint. Please note that this feature functions in the Cool Mode only. Your
TotalTouch™ Thermostat must be configured to control a cooling unit such as an
air conditioner of heat pump. Once you choose De-Humidify follow these easy steps:
The DH setpoint with – and + icons allow you to lower and raise your setpoint
Example of typical use of the De-Humidify function: If the current humidity is 70%
your TotalTouch™ will initiate the humidifier to function until Setpoint 50% in this reached.
In order to de-humidify you must set the de-humidify setpoint below the current rel-
ative humidity. Your TotalTouch™ will both lower and regulate temperature to the
cooling setpoint while monitoring and lowering the room humidity.
Since the De-Humidify feature uses the Cool Function of your Air Conditioner or Heat
Pump, your TotalTouch™ thermostat will turn off the air conditioning if either the dehu-
midifier setpoint or temperature setpoint is reached – which ever comes first.
28

FAN OPERATION MODE

There are three modes of fan operation: Fan Auto, Fan On, Fan Off. When
the fan is running, the animated fan icon will appear on the Home Page.
FAN AUTO: The fan will run on only when there is a demand for heating or
cooling.
FAN ON: The fan runs continuously
FAN INTERMITTENT: The fan will run 10 minutes per 1/2 hour providing a
convenient way to improve air quality and save energy.