Crown CTs600 Service Manual page 7

Professional power amplifiers
Table of Contents

Advertisement

o. Place jumpers on Z104 and Z105.
p. Adjust R379 for the voltage determined on step n +/-0.25V.
q. Remove the Z104 and Z105 jumpers.
r. Repeat steps b through q for CH2
3.
Program PIP Serial EEPROM
Address
Example
0000h
0001h
0002h
0003h
0004h
0005h
0006h
0007h
0008h
0009h
000Ah
000Bh
000Ch
000Dh
000Eh
000Fh
0010h
0011h
0012h
0013h
0014h
0015h
0016h
0017h
0018h
0019h
001Ah
001Bh
001Ch
001Dh
001Eh
001Fh
0020h
0021h
0022h
0023h
0024h
0025h
Description
Data
43
Manufacturer Name in ASCII = 'CROWN'
52
4F
57
4E
Note: Null termination indicates end of data.
0
0
0
0
0
31
Serial Number in ASCII
32
33
Example = 123456
34
35
Note: Null termination indicates end of data.
36
0
0
0
0
30
Date Code in ASCII
31
30
Example = 0102
32
43
Model Name in ASCII
54
73
CTs 600 = 'CTs 600', CTs 1200 = 'CTs 1200'
20
Example = CTs 1200
31
32
Note: Null termination indicates end of data.
30
30
0
0
6E
AO1 Scaling Coefficient
0
CTs600/1200=110 ($6E), CTs2000/3000=165 ($A5)
0
Example = 110
0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cts 1200

Table of Contents