Reverse the AC plug the AC outlet and repeat AC voltage measurements for each exposed metallic part. Voltage measured must not exceed 0.3V RMS. This corresponds to 0.2mA AC any value exceeding this limit constitutes a potential shock hazard and must be corrected immediately. TOVIS CO., LTD.
Then, these adjusted settings are kept in memory even if you change resolution mode or turn off the monitor. 3-6. I C BUS control It is designed by I C BUS control for simplifying the circuit. TOVIS CO., LTD.
Your monitor starts up automatically when you insert the power plug to the power source. 5-2. Signal cable Connection Connect the 15pin-signal cable to the source and lock both screws to ensure that the monitor is properly grounded. TOVIS CO., LTD.
DEGAUSS – Do degaussing in the state that the OSD isn’t displayed. ③ DOWN/UP -When the Main-Menu is displayed, you can search each function using these keys. -When the Sub-Menu is displayed (after selecting the function), you can change each state of the screen using these keys. TOVIS CO., LTD.
Page 10
1) Press the “MODE” key then Main-Menu OSD should come out as below figure. 2) Search “BRIGHTNESS” sub-menu using the “UP/DOWN” key on the Main-Menu OSD. 3) Select the “BRIGHTNESS” by pressing “SEL” key. Then The “BRIGHTNESS” OSD color changes from yellow to red. TOVIS CO., LTD.
Page 11
“CONTRAST” use the “UP/DOWN” keys and then adjust the same way as item 3), 4) and 5). 7) To finish the adjustment press the “MODE” key then the OSD will disappear. TOVIS CO., LTD.
Page 12
ADJUST SAME WAY AS ABOVE I. PARALLELOG ADJUST SAME WAY AS ABOVE J. PIN BALANCE ADJUST SAME WAY AS ABOVE K. COLOR ADJUSTMENT. 1) Press the “MODE” key then Main-Menu OSD come out as left below figure. min->1-99->max TOVIS CO., LTD.
Page 13
1) Press the “MODE” key for the Main-Menu OSD. 2) Search “LANGUAGE” sub-menu using “UP/DOWN” key on the Main-Menu OSD. 3) Select the “LANGUAGE” by pressing “SEL” key. Then The Language sub-menu comes out as right below figure. TOVIS CO., LTD.
Page 14
Press the “MODE” and “DOWN” key simultaneously until the OSD comes out as below. The OSD factory mode is the same format as the user mode except the color Of the bottom line. (User mode is blue; factory mode is red as shown below) TOVIS CO., LTD.
1) After finishing the adjustment; search “RECALL” using “UP/DOWN” key. 2) Press “SEL” key until OSD disappears then the adjusted value is saved and exits from the factory mode. C.Adjustment. All adjustment methods are the same as the user’s control mode except “COLOR”. TOVIS CO., LTD.
Page 16
D.COLOR ADJUSTMENT. 1) Before adjusting “COLOR”, “CONTRAST” and “BRIGHTNESS” fix levels at maximum. (It’s a TOVIS’s reference condition.) 2) At the factory mode, search “COLOR” using “UP/DOWN” key. 3) Select “COLOR” by pressing “SEL” key then color sub-menu comes out as left below figure.
Page 17
TOVIS P/N MTG-1971XT DATE 2002.03.11 TOVIS REV NO. Color Monitor Service Manual PAGE 17/30 9300 GAIN 9300 BIAS 6500 GAIN 6500 BIAS GAIN BIAS. “SEL” and “UP/DOWN” TOVIS CO., LTD.
7-3.4 Focus adjustment. 1) Input the "H" character pattern with 48KHz 1024*768. 2) Adjust the focus for the best balance at each point of A, B, C, D, E as shown below by rotating the focus VR of FBT. TOVIS CO., LTD.
Page 19
At the same time, center the raster vertically. ⑦Move the yoke slowly forward until a uniform green screen is obtained. Tighten the clamp screw of the yoke temporarily. ⑧Check the purity of the red and blue raster by adjusting the bias controls. TOVIS CO., LTD.
Page 20
Adjusting the angle affects the vertical lines and rotating both magnets affects the horizontal lines ⑥.Repeat adjustment 3,4,5 Keeping in mind red, green and blue movement, because 4-Pole Magnets and 6-Pole Magnets interact and make dot movement complex. TOVIS CO., LTD.
Page 22
Vertical position is controlled by IC601 using I 4) East-west parabola A parabola waveform is available on pin 24 of IC301 for driving the pincushion correction stage. Amplitude of parabola waveform is controlled by IC601 using I TOVIS CO., LTD.
Page 23
Q316,Q317 is off when horizontal frequency is 37KHz. Q316,Q318 is off when horizontal frequency is 43KHz-52KHz. Q317,318 is off when horizontal frequency is 53KHz∼ 61KHz. Q316,Q317,Q318 is off when horizontal frequency is 62KHz∼ 70KHz. Q316,Q318 is off when input is override condition. TOVIS CO., LTD.
Page 24
Q405, Q406 and Q407, which is operated by I2C BUS control through u-com, adjust cutoff voltages. 8-8.3. OSD (On Screen Display : IC403) The OSD signal is applied from IC403 to IC402. It is controlled by I C BUS control line. TOVIS CO., LTD.
9-1. NO POWER NO POWER CHECK C101 AC LEVEL CHECK & REPLACE F101, POWER CORD, F101 CHECK C104 DC LEVEL CHECK & REPLACE BD101 CHECK IC101 #1 WAVEFORM CHECK & REPLACE IC101 CHECK & REPLACE SECONDARY VOLTAGE OF T101 TOVIS CO., LTD.