This manual is provided to acquaint you with the
dehumidifier so that installation, operation and
maintenance can proceed successfully. Ultimate
satisfaction depends on the quality of installation
and a thorough understanding of this equipment.
The dehumidifier is built around tested engineering
principles and has passed a thorough inspection for
quality of workmanship and function.
Providing 150 pints of water removal per day at
standard rating conditions (80ºF/60%RH), the Quest
150 Dual will effectively control humidity while using
only 10.9 amps/115V.
Features:
High capacity
High efficiency
Environmentally friendly
Patent pending dual-air distribution
Patent Pending Dual-Air Distribution
quest
quest
Asset Protection and IAQ Solutions
Specifications subject to change without notice.
Water Removal Rates (Pints/Day)
150 pints
4201 Lien Rd
Madison, WI 53704
www.QuestProtect.com
1
80˚F, 60% (AHAM)
Phone 608-237-8400
Toll-Free 1-800-533-7533
sales@QuestProtect.com
TS-880
11/14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the quest 150 dual and is the answer not in the manual?

Questions and answers

Summary of Contents for Therma-Stor quest 150 dual

  • Page 1 Quest Dry Quest 150 Dual Installation, Operation and Maintenance Instructions Installation, Operation and Maintenance Instructions – Read and Save These Instructions – This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully. Ultimate satisfaction depends on the quality of installation and a thorough understanding of this equipment.
  • Page 2: Table Of Contents

    Quest 150 Dual Installation, Operation and Maintenance Instructions Table of Contents Safety Precautions ............. 3 1. Intended Application(s) .......... 4 2. Registration ............4 3. Specifications ............ 4 4 . Installation ............5 4.1 Remove Compressor Shipping Support ... 5 4.2 Location ............
  • Page 3: Safety Precautions

    Quest 150 Dual Installation, Operation and Maintenance Instructions Safety Precautions Read the installation, operation and maintenance instructions carefully before installing and operating this device. Proper adherence to these instructions is essential to obtain maximum benefit from your Quest 150 Dual indoor air quality system.
  • Page 4: Intended Application(S)

    1. Intended Application for Quest 150 Dual The Quest 150 Dual is intended for use in light commercial structures: however, the unit can be placed in almost any setting where dehumidification is desired. Use in highly corrosive applications and pool areas may void warranty.
  • Page 5: Installation

    2. Locating near a floor or other suitable drain. 3. Mount 4” above drain. 4. Do not install the Quest 150 Dual with the exhaust of the unit within 1’ of a wall or obstruction. Do not place the unit near open water.
  • Page 6: B Duct Outlets

    A more simplified remote installation method than above uses ducting between the Quest 150 Dual discharge and the humid room; the Quest 150 Dual inlet draws air from the room in which it’s located. This works well if there is an adequate air flow path between the two rooms; e.g. high door undercut or wall grill.
  • Page 7: Install Leveling Feet

    4.5 Condensate Water Removal The Quest 150 Dual drains via gravity, therefore, it does not have the ability to push condensate (water) uphill. The drain hose must run downhill toward the drain location. Condensate can be drained by using the 5/8”...
  • Page 8: Ducting

    Improper installation of the drain hose may result in water leakage. If the Quest 150 Dual is located too far from the floor drain and the provided hose does not reach, you may use a 1/2” PVC rigid pipe to extend the drain. Rigid PVC tubing is readily available from your local hardware store.
  • Page 9: Fan Switch

    7.1 Air Filter The Quest 150 Dual ships with a standard MERV 8 pleated fabric filter. This should be checked every six months. The pleated fabric filter can generally be vacuumed clean several times before needing replacement.
  • Page 10: Service

    8.1 Technical Description The Quest 150 Dual uses a refrigeration system similar to an air conditioner’s to remove heat and moisture from incoming air, and add heat to the air that is discharged. Hot, high pressure refrigerant gas is routed from the compressor to the condenser coil.
  • Page 11: Troubleshooting

    Quest 150 Dual Installation, Operation and Maintenance Instructions 8.2 Troubleshooting FOR THE USER: If the unit does not work properly, please check the following: — Is the unit unplugged? — Is power to outlet on? (check switch, if applicable) — Is circuit breaker tripped? —...
  • Page 12: Service Parts List

    Quest 150 Dual Installation, Operation and Maintenance Instructions Evaporator coil frosted continuously, low dehumidifying capacity. Dirty air filter or air flow restricted. Defrost thermostat loose or defective. Low refrigerant charge. If none of the above has fixed the issue, call technical support at 1-800-533-7533.
  • Page 13: Wiring Diagram

    Quest 150 Dual Installation, Operation and Maintenance Instructions 11. Wiring Diagram quest quest 1-800-533-7533 www.QuestProtect.com Asset Protection and IAQ Solutions sales@QuestProtect.com...
  • Page 14: Warranty

    (but all warranty periods will be extended by the period of time, if any, that the Quest 150 Dual Dehumidifier is out of service while awaiting covered warranty service).

Table of Contents